animal incinerator manufacturer

Spare part list- ignition burner

Item description                                                No of required

Motor     2

Control box  2

Pump couplings   4

Photo cells    2

Sets ht. leads       2

Sets electrodes    4

Oil valve       1

Nozzle   2

 

Parameter Compliance

Type of Waste To treat medical waste, categories A,B,C,D,E

Type of Incinerator Pyrolytic

Nominal Burn rate 50 t0 60 kg/ hr at 3500Kcal/Kg

Loading Manual, Batch Load

De  Ashing Automatic or Manual batch de ashing

The incinerator must avoid the release of black smoke and fine dust during the loading

Primary chamber capacity 2-3 m³

The insulation   of the combustion chamber should be composed   of refractory bricks, having a higher content of

aluminium and insulates,

The plate of combustion in carborundum avoiding the fixing of glass and slags

Hours of operation /Day >10 hrs

Max Operating Temperatures 1400 °C

Normal Operating Temperatures(Primary)  >850 °C

Operating Temperature(Secondary) >1100 °C

It should have digital temperatures regulator( Temperatures regulator in digital watch)

Carbon content of ashes <2%

The installation should be completely free from visible smoke as well as offensive odours

Residence time in second chamber 2 second minimum

The internal diameter of the Chimney :Ø 400

Height of stack >8m

Burner operation Automatic On/Off

Fuel Diesel

Fuel consumption at raed capacity >7kg waste /ltr

Electricity consumption <2kW at rated capacity

Operating Voltage 220 – 240V AC 50Hz

Spare parts Supply for 1 year quoted as option

Consumables Supply for 1 year of operation to be mentioned as option

Warranty Parts and service support: 1 year minimum post comissioning

Service support <72 hours

Emission standard Compliance BS3316 or equivqlent standard

Process filtering system Scruber to be mentioned as option

CE Manufacturing Compliance BS EN 746-2-1997

Design Specification Type A,B,C,D,and E of medical waste

Installation and Comissioning  Included in condition of supply

Training in preventive and curative maintenance and use of the incinerator Operator training inclusive in offer

Capacity to treat Plastic Not less than 40% by weight