Author: admin

HICLOVER Waste Burner Front view

— Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator. — — Single combustion chamber, double burning chambers, three burning chambers as well as multi-combustion chambers waste incinerators. — — System remedies for clinical waste environmental. — — High shed price, from 5kgs to 1000kgs per hour.— — New Design for pet dog animal cremation company. — — HICLOVER, relied on partner with years

Read More
Burner manufacturing facility

Key Features: — — Complete variety burner with Saved money Tiny Range incinerator, Criterion Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation,  Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator. — Single combustion chamber, double combustion chambers, three combustion chambers and  multi-combustion chambers waste incinerators. — System solutions for medical waste environmental. — High burn rate, from 5kgs to 1000kgs per hour. — New Design for pet animal cremation business. — HICLOVER, trusted partner with years of experience. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel: +86 -25 -8461 0201 Mobile: +86-13813931455(whatsapp/wechat) Website: www.hiclover.com   Email: [email protected] Email: [email protected]   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30

Read More
HICLOVER Made Waste Incinerators

HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project. We supply single burning chamber, double burning chambers, 3 combustion chambers and also multi-combustion chambers waste incinerators for lab, clinic, healthcare facility, clinical center, hygiene scientific waste damage with clinical disposable,

Read More
Pet Dog Animal Crematory Incineration

Incineration is the most obvious solution for total destruction of municipal waste, avoiding  all the direct and indirect risks associated with other disposal methods. Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the  same place where it was generated to avoid cross-contamination risk and to keep waste treatment costs at acceptable level. ※ Main Feature:–– 3 Burning Chambers or A/B Main Burning Chamber— — Dual or Three Italy Heater–– Burning Rate: 80-800kgs per hour–– Burning Chamber: 1.0M3-10.0 M3 ※ Optional Function/Parts/Material/ Burning Price: — — Stainless Steel Smokeshaft — — Dry Smoke Filter Chamber— — Smokeshaft Elevation Customized Made— — Semi-Automatic Waste Feeding—

Read More
HICLOVER INCINERATORS

Medical waste is posturing a growing problem all over the world, jeopardizing the wellness of staff, individuals, disposal employees and anybody else entering contact with the often dangerous materials discarded by hospitals and other health care sites. Hospital waste varies from website to site and also the most significant difficulty is to dispose of this

Read More
incinerator Model TS150

HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products and friendly service. Medical waste is posing a growing problem all over the world, jeopardizing the health of staff, patients, disposal workers and anyone else coming into contact with the often hazardous materials discarded by hospitals and other healthcare sites. Hospital waste varies from site to site and the biggest challenge is to dispose of this wide range of waste streams. Incineration is still the preferred way to process medical waste without endangering the heath patients, staff or anyone else coming into contact with them. Clinical waste is costing more and more to dispose of safely. Health Clinics and Health center can now handle their own waste streams using one of our specialist medical incinerators. Destroying hazardous waste at source is by far the most effective and efficient way of handling waste that could potentially spread diseases or viruses. WWW.HICLOVER.COM|Waste Incinerators WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Website: www.hiclover.com   Email: [email protected] Email: 

Read More
Incinerators QA

Q: what is kind of waste can use in this equipment? A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any  explosive and radiation material, liquid waste and gas waste. Q: The Residency time in second burning chamber Tel: +86 -25 -8461 0201 not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity.   Clover incinerator use time per day up to 24 hours. Between each feed/combustion time,  there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion  time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use.  Generally, we proposal small laboratory, small clinic use capacity under 20 kgs per hour.  When incinerator use in hospital, please calculate the waste output capacity around 2kgs  per people per day. If there are 200 sickbed in the hospital, that’s mean you need one  incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs  per hour. According the operation time per day, waste material, budget,  development, etc, you can use capacity from 30-50 kgs per hour incinerator. *How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. Q: Assembly and Testing A: We supply all documents and incinerators easy to installation and operation. Customer  can send people come to our factory to learn installation and operation. Generally,  We do not send engineer to local site if not request. The dispatch cost is extra according to order. Q: Combustion Temperature A: The first combustion chamber: 800-1000 centi degree. The second combustion chamber: 1000-1200 centi degree. Q: Incinerator Control Mode A: Default Control mode is common control case. PLC mode according to model and order. Q: Operation and maintenance costs A: Operation cost according to fuel consumption rate and power/staff, etc.  Annual around $500-$1000usd per year maintenance according model, use situation.  One person can service 02 unit incinerators. The staff should have basic electrician  knowledge to operate/inspect/maintaince incinerator/burner/blower according to  operation user guider, and know risk of medical waste to protect worker self with necessary protection element. Q: The Residency time in secondary combustion chamber A: 02 sec. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat) Website: www.hiclover.com   Email: [email protected]

Read More
medical waste products burner

an incinerator suitable for chemcial waste containers. ability concerning 100 kgs per hr with a scrubber.1- One system of medical waste materials incinerator – – Ability: 100 kg–– Gas: gas oil 2 -One system of typical waste products burner – Capability: 150 kg –– Fuel: gas oil this type of capability will be a waste

Read More
an incinerator for our dental clinics

a burner for our oral clinics.The burner need to follow” Technical Standard NTON 05-015-02 Monitoring as well as Solid Waste Disposal Hazardous carbon monoxide go “, in addition to meeting worldwide requirements capability requirements for new fixed resources and discharges from the Epa United States (Epa EPA) Incinerators Medical and also Medical facility contagious waste

Read More