Incinerate: medical waste and general waste
Capacity to burn waste: 400 — 500 kg/hr
Fuel: Diesel
Fuel Consumption: 10 litres/hr maximum
Incineration temperature: 950 – 1300 °c
Casing: thick (min 5 mm) Stainless steel casing and fully
insulated to withstand sea humidity
Voltage: 220/240 V or 380/415V
Frequency: 50 Hz
Feeding: automatic
Ash 1 leftovers removal: Automatic
Fuel gas filtration system: Yes
Warranty: 12 months
Staff training: Operator & Maintenance staff
Operation and service manuals: 3 sets each
containers, leaves, etc;
1.The double chamber incinerator shall preferably be designed. Air supply in the primary and secondary chamber shall be
regulated between 30%-80% and 170%-120% of stoichiometric amount respectively. Flow meter/suitable flow measurement
device shall be provided on the primary and secondary air ducting. The combustion air shall be supplied through a
separate forced draft fan accounting for the air supplied through burners. Provision shall be made in the primary
chamber to measure the water column pressure.
chamber and 1200 dc in the secondary chamber. The refractory& insulation bricks shall have minimum 115mm thickness each
& conform to IS:8-1983 & IS:2042-1972 respectively.
heat resistant aluminium paint suitable to withstand temp.of 250 dc with proper surface preparation. Refractory lining
of the hot duct shall be done with refractory castable (minimum 45mm thick)& insulation castable(minimum 80mm thick).
Ceramic wool shall be used at hot duct flanges & expansion joints.
5.There shall be a separate burner each for the primary & secondary chamber. The heat input capacity of each burner
shall be sufficient to raise the temp.in the primary & secondary chambers as 800+/- 50dc and 1050+/-50dc respectively
within maximum of 60 minutes prior to waste charging. The burners shall have automatic switching off/on control to
avoid the fluctuations of temperatures beyond the required temp.range.
6.Incinerator shall have graphic or computer recording device which shall automatically and continuously monitor and
record dates, time of day, batch sequential number,Co,Co2,O2 in gaseous emission shall also be measured daily.
6mm plate steel sheel construction
11cm 1400 o C Refractory L iner
Temperature controlled Burners
Secondary combustion Burners
Interlock Switch on Load Doors
Separate Ash Door
One Second secondary Residence @ 1000 o C
400 ° C Silicone Based Paint Finish.
Alloy Temperature Sensor
Factory wired and tested
Capacity-20 kg / hr
Primary Chamber-1607 L
Hearth Area-1:36 sq. m
Secondary Chamber-694 L
Primary Burner (oil)-420,000 btu
Secondary Burner (oil)-900,000 btu
secondary Combustion-1/6 hp
Exhaust Stack-46cm x 6m
Electrical Service-220/50
Weight System-5.700 kg
Dimension “D”-152cm
Load Port Height- 60x 60 cm
Ash Port Height -36 x 36 cm
with minimum of 3mm thick natural hard rubber suitable for the duty conditions and shall also conform to IS:4682 part
I-1968 to avoid corrosion to oxygen and acids in the flue gas.
INCINERATEUR DE DECHETS HOSPITALIER