Tag: medical waste incinerator

scientific waste incinerator china

medical waste incinerator china, Design, supply and manufacture ex works of one Surefire Manual Load TS50/1 Medical/General waste incinerator as detailed below: – ·         Waste type: Mixed type o,1,2,3,&4 hospital/clinical bio hazard waste ·         Waste density: 125 to 350Kg/M3 ·         Waste CV: 4000 KCAL/kg ·         Moisture content: 10-25% ·         Estimated ash residue: 5-10% ·         Nominal

Read More
portable incinerator manufacturers

Tanque Capacidade mínima: 500L Provido de estrutura de suporte Válvulas Indicador de nível de tanque Funil Filtro de impurezas na boca do tanque     comprising of, as a minimum, electronic ignition and all necessary interlocks and safety devices to provide safe   operation. The chamber and burner shall be designed to maintain a minimum

Read More
medical waste incinerator china

medical waste incinerator china, Design, supply and manufacture ex works of one Surefire Manual Load TS50/1 Medical/General waste incinerator as detailed below: – ·         Waste type: Mixed type o,1,2,3,&4 hospital/clinical bio hazard waste ·         Waste density: 125 to 350Kg/M3 ·         Waste CV: 4000 KCAL/kg ·         Moisture content: 10-25% ·         Estimated ash residue: 5-10% ·         Nominal

Read More
professional waste heater

medical waste incinerator: medical waste and general waste Capacity to burn waste: 400 — 500 kg/hr Fuel: Diesel Fuel Consumption: 10 litres/hr maximum Incineration temperature: 950 – 1300 °c Casing: thick (min 5 mm) Stainless steel casing and fully insulated to withstand sea humidity Voltage: 220/240 V or 380/415V Frequency: 50 Hz Feeding: automatic Ash

Read More
hog insinerators

Finish All equipment shall be painted with a coat of zinc rich primer and two coats of high temperature heat resistant polyurethane type paint. All painted surfaces shall be prepared by either steel shot cleaning or sand blasting.   Identification and Name Plates Identification and name plates containing the manufacturer’s name, model number, serial number,

Read More
medical waste incinerators manufacturers

chemical agents to be utilized: 10% heptyl (unsymmetrical dimethylhydrazine) water solution, heptyl (unsymmetrical dimethylhydrazine) vapour with 0.8 to 1.0 kg/m3 concentration, 10% azotic (nitric) acid water solution, azotic (nitric) acid vapour with concentration up to 1.1 kg/m3; 2.    neutralization method: thermal decomposition; 3.    neutralization temperature: +800?C to +1200?C; 4.    performance: ?    vapour capacity: 70 to

Read More
medical waste incinerator

medical waste incinerator: medical waste and general waste Capacity to burn waste: 400 — 500 kg/hr Fuel: Diesel Fuel Consumption: 10 litres/hr maximum Incineration temperature: 950 – 1300 °c Casing: thick (min 5 mm) Stainless steel casing and fully insulated to withstand sea humidity Voltage: 220/240 V or 380/415V Frequency: 50 Hz Feeding: automatic Ash

Read More
small scale medical waste incinerator

Toxic and dangerous wastes, Medical pharmaceutical and hospitable liquids  Wastes Domestic garbage Electric and electronic wastes Industrial wastes In General, all type of wastes and garbages Capacity 50-60Kg/h Combustion supporting materials Coal oil, diesel oil Temperature inside 800-10000C 1000-12000C Burning efficiency >98% Power consumption 1.3KW Noise <78dB Index of let smoke and waste gas Ringelman’s

Read More
medical waste incinerator for sale

Waste type: health care waste Waste density: 125 to 350Kg/M3 Waste calorific value: 4000KCAL/kg Moisture content: 10 – 25% Estimated ash residue: 5 – 10% Nominal capacity: 50kg/hr batch load Secondary chamber: 2 [email protected]?C Environmental: NEMA ACT (EMCA) 1999, Waste Management regulations, 2006 Primary Combustion chamber: The primary combustion chamber is the main structure of

Read More
Waste Incineration HICLOVER Model TS75

Waste Incineration HICLOVER Model TS75  Items/Model TS75( PLC) Photo Concept Waste Incineration Burn Rate Average 75 kg/hour Feed Capability Common 150kg Control Establishing PLC( Programmable Thinking Controller Burner) Burning Chamber 770L Inner Measurements 100x81x95cm Second Chamber 385L Smoke Filter Chamber Yes Feed Setting Manual Voltage 220V Power 0.7 Kw Oil Consumption (kg/hour) Common 16.9 Gas

Read More