Incinerators Organic waste disposal system (incinerator)
Burner must satisfy the adhering to specifications:
— Combustion capacity( kW )= 581+/ -10 %
— Combustion capacity( kcal/h )= 500,000 +/ -10%
— Max. l/h( at approx. 50% water content )= 100+/ -10%
Further specifications will be offered with the query.
The burner will be fully self contained.
The burner plant shall include a control board for its procedure. On the control panel we shall have an aesthetic display screen of the chamber temperatures. This visual screen should manage as well as check the incinerator and also his performance.
Ability of destruction in weight will be 60 Kg/h.
It should have the ability to run not less than 10 hours/day
This incinerator must be able to ruin all combustible wastes produced by medical facilities, personal centers, research laboratories, institutes, and so on.
Style Spec: Kinds A, B, C, D, and also E of clinical waste
“PYROLYTIC” burning, by regulating the gasification of waste.
The incinerator need to stay clear of the release of black smoke and fine dust, during the loadings.
It will be able to decrease the quantity of wastes by 98%.
It will be able to hold discharge in the 2nd burn with gas residence of not less than 2 seconds.
The incineration need to be entirely free from visible smoke as well as offending smells.
1.0 The primary ignition heater shall providing ignition of the waste to 850 ° C and must turn off to conserve gas.
The main combustion chamber will be created from hefty steel plate as well as the system is internally lined with a full layer of hote face refractory as well as high performance insulation.
The Internal size of the Smokeshaft at the very least:? 400 and its elevation: 8 m
The Quantity of the combustion chamber a minimum of: 1.200 L
The Measurement of the door for filling in cm a minimum of: 70 × 70.
Burner procedure ought to be Automatic On/Off Fuel?: diesel
Manufacturer to give necessary details for the very best of the installment
The control board shall have all suitable audible and aesthetic alarms to make sure safe operation.
This burner with” PYROLYTIC “burning need to have: 1.
A burning chamber of waste: oPerfectly tight door for the hands-on loading of waste. The loading should be Manual, Set Load oA heater of lighting which the use is restricted to the ignition of waste. oFrontage of loading with door seals increased on joints, wheel of screw plug, flexible joint, as well as stuffing protecting out of refractory. oThe insulation of the burning chamber need to be composed of refractory bricks, having a high web content of aluminium as well as insulates bricks in order to ensure a minimum temperature outside sheet metal. o Structure of the refractory;
? Refractory concrete:. Density: ≥ 100 mm. Nature: 42 %of Al203? Insulate in fibrous panels: Thickness: ≥ 75 mm Nature: Calcium silicate.? Burner of illumination of waste, with fuel, conventional mono-bloc spreading directing plunging fire, illumination and also safety and security of digital ignition, irreversible ventilation,
electromagnetic sluice gate of regulation and isolating valve.
Plate of combustion in Carborundum, preventing the fixing of glass as well as slags
A chamber of post burning of gases oA heater of burning of gases, oA gadget of injection of air allowing a complete recombustion of gases, oA tool of air inlet of air conditioning of waste gases, oA sheath of discharge of the gases charred. oCarcass in solid
sheet steel with assistance of connection. oComposition of the refractory;? Refractory concrete:? Thickness: ≥ 150 mm? Nature: 65% of Al203? Insulate in fibrous panel:? Density: ≥ 85 mm? Nature: Calcium oBurner with gas, mono-bloc spreading directing kind with straight flame, illumination as well as safety and security of digital ignition, long-term ventilation, electromagnetic sluice entrance of regulation and also separating shutoff.
oA second shot of air to guarantee excellent oxygen material.
A control box guaranteeing the complete cycle of combustion.
Follower: oElectro-ventilator dispersing the second air, the regulation of the air circulation being carried out by valves and also adhering to the control of the automated cycle. Controls and also guidelines: Control box watertight to dust, consisting of:
A button circuit breaker for every engine (ventilators as well as burners). A timer with flexible temporization for the guideline of each burner. A regulator with watch for the temperature level of burning. A regulatory authority with digital watching for the temperature of message burning. Electric box
The secondary
burning chamber should damage the pollutant item and must resist to high temperature( 1100 ° C)
Refine Filtering system: Scruber to be mentionned as optional