Power

kW

Mcal/h 178 – 356

153 – 306

Fuel consumption rate L/h 15 – 30

Fuel Domestic fuel oil

Internal calorific value kWh/kg

Mcal 11.8

10.2 (10,200 kcal/Kg)

Density kg/dm3 0.82 C 0.85

Viscosity at 20°C mm2/s max 6

Operation Intermittent (1 min stop in 24 h)

One speed (on or off)

Sprinkler Number 1

Standard use Water, steam, diathermic oil boiler

Ambient temperature °C 0 C 40

Combustion Air Temperature °C max 60

Combustion temperature  °C 900 to 1100

Destructive capacity Kg/h (l/h) 120 (1600)

Power supply V

Hz 230 +/- 10%

50 single-phase

Electric motor rpm

W

V

A 2800

0.25

230

2.1

Motor capacitor µF/V 8/450

Ignition transformer V1 – V2

I1 – I2 230V – 8kV

1.8A – 30mA

flow 12 bans

Pump – pressure range

temperature

kg/h

bar

°C max 65

10 C 18

60

Degree of protection IP 40

Power consumption w max 0.43

Chimney height  m 6 to 8

Chimney diameter  mm Approximately 500

Tank volume  l 1000 to 1200

Number of ovens  2 to 3

Dimensions of the loading door cm About L80 x B60  

Combustion chamber: One-piece casing made of 3- and 10-mm thick sheet steel. Loading front with sealed door mounted on hinges, screw-type closing wheel, flexible seal, and refractory insulating lining.

Chamber materials made of refractory concrete with an alumina content of 42%AL2O3 and a wall thickness of 115 mm. Equipped with thermal insulation in fibrous panels made of calcium silicate with a thickness of 75 mm. It must also be equipped with a waste ignition burner.

Post-combustion chamber A post-combustion chamber for gases meeting the emission standards for certain gases (CO, HCl, SO2, NOx, etc.). 

Filter  Allowing combustion control and regulation of the treatment process;

A filter for reducing air pollution from incineration

Metal scraper  A metal scraper and an ash pan with handling handle.

Paint: light blue