Medical waste, disposable syringes, infusion sets processing, cotton yarn, the operating room, the residual limb, waste rubber gloves, 

protective clothing and infectious and harm venereal hospital bed supplies, general wastes.

 

Incinerator Items/Model HICLOVER YD300(PLC) HICLOVER YD500(PLC)
Burn Rate (Average) 300-500 kg/hour 500-600 kg/hour
Feed Capacity(Average) 480kg/feeding 800kg/feeding
Control Mode PLC Automatic PLC Automatic
Primary Combustion Chamber 2400L(2.4M3) 4000L(4.0M3)
Internal Dimensions 220x110x100cm 257x147x108cm
Secondary Chamber 1200L 1500L
Smoke Filter Chamber Yes Yes
Feed Mode Manual Manual
Voltage 220V 220V

 

Burning temperature First combustion chamber: 800- 900 ℃ ; Secondary combustion chamber:2000℃

Flue gas residence time≥1s

FURNACE BODY TYPE

Vertical closed furnace combustion chamber

BURNING CAPACITY 10-20kg/time (daily burn 3-6times, each time consume about 1 hour) total daily waste capacity 120 kg

IGNITION MANNER

automatic

FUEL TYPE

0# or-20# diesel or natural gas

FEEDING MODE

Solid waste manual feeding

TAKE ASH MANNER

manual

FURNACE INNER PRESSURE adopt negative pressure design, no back-fire,―3~―10mmH2O

DESIGN HEAT VALUE waste mix 2000kcal/kg  ~5000kcal/kg,0# diesel 20000kcal/kg

FLUE GAS TREATMENT

Gasification combustion chamber(first combustion chamber) +

MANNER

blower + mixed combustion chamber+ high temperature secondary combustion chamber + flue gas purification room (calcium hydroxide filter brick) +exhaust fan +

independent chimney.

Furnace body type Vertical closed furnace combustion chamber

Burning capacity 10-20kg/time (daily burn 3-6times, each time consume about 1

hour) total daily waste capacity 120 kg

Ignition manner automatic

Fuel type 0# or-20# diesel or natural gas

BURNING TEMPERATURE First    combustion    chamber:    800-900   ℃ ; –800℃–1000℃

Secondary combustion chamber:2000℃–1000℃-1300℃

Feeding mode Solid waste manual feeding

Take ash manner manual

Furnace inner pressure adopt negative pressure design, no back-fire,―3~―10mmH2O

Design heat value waste mix 2000kcal/kg  ~5000kcal/kg,0# diesel 20000kcal/kg

Flue gas treatment Gasification combustion chamber(first combustion chamber) +

manner blower + mixed combustion chamber+ high temperature secondary  combustion  chamber  +  flue  gas  purification room (calcium hydroxide filter brick) +exhaust fan + independent