Type Pyrolytic:- Hot Medical Waste Disposing Machine

Operation Condition 8-16 Hr /day

Controls Built in data recording

Incinerator 

/Primary Combustion Chamber Type: continuous loading 

Capacity/Burn rate per hour: 250 -300kg/hr 

Temperature:  900-1200 oC

 

Material:

External- 3 layers 

Internal lining:  a fire proof material of pre-fired refractory bricks with Aluminium lining, resistant to corrosive waste or gas and to thermal shock

Secondary 

Combustion 

Chamber Type: horizontal/vertical

Temperature: 1200-1400 oC

Residence time of gases : >2 seconds

Material

External- Low thermal mass insulation 14-30 oC 

Internal lining:  a fire proof material of pre-fired refractory bricks with Aluminium nettle lining, resistant to corrosive waste or gas and to thermal shock.

Ash Handling System Both Automatic and manual removal of Ash. Must ensure removal/treatment of hazardous remnants of ash.

Flue gas treatment   system  

 

 

  Capable of treating the flow of flue  gas as the incinerator is operating at its maximum capacity

Auxiliary device: Water level gauge, pressure sensor, PH sensor..etc. 

Auxiliary device: Fuel cut off device

Waste  feeding mechanism Automatic pneumatic/hydraulic waste loading system or conveyor belt , capacity 650-800L at a time                                                                                                                                      

Chimney (Stack) Type: Vertical type

height: 7-10 meters 

Material: Fireproof cast, stainless steel 

Wet scrubbing system Vertical sprat tower with baffles or packing inside

Gas emission Reduction of Pollutant gas SO2, HCL, HF and line particulate

OUTPUT ASH -Max <5% of original waste size

GAS- SMOKELESS,ODORLESS

Emission standard WHO/ European

Test report for emission testing Must be provided

Product Data sheet/ Catalogue Must be attached to the ITB

Additional Requirement -Local agent or branch in Ethiopia

-Training for users as well as for EPHI maintenance staff  on preventive maintenance

-Fuel tanker with a minimum capacity of 2500 litre (made of plastic material with overfill prevention valve ,fuel gauge, lifting eyes)

-The bidder should be willing to sign at least a five years’ service and maintenance agreement with the client (EPHI)

-The supplier shall arrange by itself lifting equipment and labour needed during the installation, testing and commissioning of the incinerator