UNAMID  supports  its  dependants  via  the  operation  of  several  self-sustained  camps located  across the  mission  AOR.   These camps contain  all elements representative of small communities.  These communities include hospitals and medical  facilities, power generation  stations, grocery shops, kitchen  and dining facilities and large scale use of packaged   material in plastic,  cardboard and similar. The waste generated  in  these camps  are  therefore   representative   of  average   small   communities without   heavy industry.   The  main objective of this document  is  to  provide potential bidders  with necessary   information   to   supply   the   large   capacity   containerized   incinerators   to UNA M I D as described  in subsequent clauses.

1. Medical waste incinerator – Small

2. Medical waste incinerator – Medium

3. General waste incinerator – Small

4. General waste incinerator – Medium

5. General waste incinerator – Large

5. General waste incinerator – Large with automated feeding system

Supply of Medical and General waste incinerators

FOR THE PROVISION OF

LARGE CAPACITY CONTAINERIZED INCINERATOR AND ACCESSORIES

The proposed   incinerators shall  be  built  into standard  20ft  lSO contai ners or alternatively built into similar footprint complete with  ISO load  handling facil ities (hooks噜  eyelets, etc). The number of conta iners/container sized  modules required  for each  unit is at the discretion of the Contractor.

•Thermocouple

•temperature gauge

•fire rope 

•burn er  

•induction air fan

•digital temperature display panel

The incinerator combustion chamber(s) should be designed for easy maintenance of all internal parts including the refractory and insulation. Materials used in the individual parts of the incinerator shall be heat resistance and also be protected against oxidation, corrosion , etc. The incinerator shell shall be made of mild steel with an adequate thickness (minimum 15 mm) and painted externally with heat resistant aluminium paint suitable to withstand 250 °C. The outside surface temperature of the incinerator casing should not exceed 50 °C above ambient temperature and shall include a safety mesh around all hot surfaces. Cold face refractory lining of calcium silicate or superior material, minimum thickness 100mm.

•Heavy steel construction.

•Fixed hearth geometry and starved air gasification operationa l mode.

•Hot face refractory concrete-ceramic suitable for thermal shock up to  1400 Celsius and abrasion. Minimum thickness  150mm.

•Cold face refractory lining of calciu m si l icate or superior material, minimum thickness 100mm.

•Refractory  lining of all the ducts shall be done with refractory castings. Su perior quality ceramic wool shall be used at all hot duct flanges and expansion j oints.

•Multi ple electric ignition fuel bu rners designed to use automotive d iesel fuel.

•Flame of the primary burner shall be oriented towards the center of the uni t which does not impinge directly on the refractory floor or wall. The secondary burner shall be positioned in such a way that the flue gas passes through the flame.

•The unit shal l prevent leakage of the hot flue gas and any backfire.