Incinerator Model TS10 PLC, Overview

 

This model Construction is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. Waste feed chamber is 100Liters (0.1m3, TS10 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation.

Combustion Chamber Volume (m3) 1.25m3

Gas Retention 2-3 Seconds

Operational Temperature Minimum 850°C for the primary chamber; min 1100

oC for the secondary chamber.

Metal Thickness 4mm

Average Ash Residue (%) 3%

Dimensions (l, w, h) 1.85m x 1.11m x 8.10m

Shipping Weight (kg) Up to 6 tonnes- anything less not acceptable

Fuel Consumption 13 – 18 liters per hour

Burn Rate* up to 100kg per hour

Thermostatic Device Included

Door Size (m) 0.64m x 0.54m minimum for ease of loading

Stack The chimney should have a minimum height of 10 meters above ground level and clear the highest point of the building by not less than 3 meters for all roofs. The topography and height of adjacent buildings within 50 meters radius should be taken into account. Point for the measurement of emissions shall be provided.

The addition of dilution air after combustion in order to achieve the requirement of these guidelines is unacceptable.

Diesel Tank A reinforced steel tank with a capacity of min 500 litres. The diesel tank shall come complete with a stand and connection valves.