SPECIFICATIONS OF A DIESEL FIRED INCINERATOR

Incinerator type: Animal waste incinerator

Load Capacity minimum:  1500 kg

Burner fuel type:  Diesel

Burner fuel rate max.:   20-25 Liter diesel/ per hour

Burners minimum: 3

Burning rate minimum: 200-300kg/per hour

Furnace bar area minimum: 2 м3

Fuel tank capacity minimum: 300L

Main chamber burning temperature min. 1100 0C

Afterburner chamber burning temperature min.  1300 0C

Power supply 220V

Incinerator items and electrical appliances should be weather proof and humidity resistant within the range of 30-90 %

Incinerator should be compliant to the environmental protection rules in accordance to national legislation

Maximum dimensions C Length C 5m, width C 3.5m, height C 5m

INCINERATOR, DIESEL, FIRED.

Specifications Indicate if item offered complies with each specification. 

1.1 General description

 

The incinerator should be a modern waste disposal unit, designed to bum medical waste in a clean and environmentally efficient manner. It should employ a temperature based logic control system to provide optimum control of the operating conditions and incorporate a high capacity thermal oxidizing secondary chamber. It should be designed to retain the exhaust gases, for at least 2 seconds to ensure the unit’s effective destruction of the combustion products.  

For the Supply, installation & commissioning of a Medical Waste Incinerator as detailed below:

i. Waste type Health care waste  

ii. Waste density 125 to 350Kg/M3  

iii.. Waste Calorific Value 4000 KCAL/Kg  

iv. Moisture content 10-25%  

v.  Estimated ash  residue 5-10%  

vi.  Nominal capacity  50Kg/hour batch load  

vii.  Secondary chamber 2 seconds @ 850°C  

viii. Environmental NEMA ACT (EMCA) 1999, Waste management regulations, 2006   

2 Equipment

2.1 Primary Combustion Chamber  

The primary combustion chamber is the main structure of the incinerator, fabricated from mild steel plate and stiffened with rolled steel sections. It is carried from the floor level on a substantial steel support frame. Internally the shell is lined with calcium silicate insulation and a hot face combination of super duty brickwork or high strength castable.  

The primary combustion chamber must ensure minimum exit temperature is not less than 850°C.  

One Manual Load Incinerator comprising:  

Manual Loading door  

Horizontal solid hearth, refractory lined primary combustion chamber. Approximate dimensions 800 mm diameters x 2100mm long  

Full sized bulk load/ash removal door  

1 off diesel-fired ignition burner ― temperature controlled  

1 off combustion air supply fan and distribution system, automatic control  

High capacity secondary combustion chamber with residence time not less than 2 seconds @ >850°C  

1 off diesel-fired afterburner ― temperature controlled  

Control panel ― automatic operation  

ð      Temperature indication primary and secondary chambers 0-1200°C   

ð      Refractory lined flanged chimney to a height of 10M above ground level  

Note: The secondary combustion chamber must ensure that the gas temperature as measured against the inside wall in the secondary chamber & not in the flame zone, is not less than 1100°C.  

2.2  Throughput  

50kg/hour at a nominal calorific value of 4,000 kcal/kg and an average bulk density of I20kg/ M3 for general waste and l60kg/ M3 for health care waste.  

2.3 Ash  

The waste will be reduced by 90~95% to leave 10 -5% ash  

2.4 Quality/Environmental Standards  

NEMA ACT (EMCA) 1999 BS3316  

2.5 Operating Period  

Anticipated daily operating period 8 hours  

Maximum operating period 12 hours  

2.6 Chamber  

Should be refractory lined to the following standard; Hearth and lower section of chamber walls  

2.7 Hot face material  

Super duty firebrick  

Limiting continuous service limit 1500°C  

Thickness 100mm  

Thermal conductivity 1.3 W/mk  

2.8 Insulation  

Calcium silicate  

Limiting continuous service limit 1000°C  

Thickness 25mm  

Thermal conductivity 0.095 W/mk  

2.9  Chimney / Stack  

Should be manufactured from refractory lined mild steel or high quality air-cooled stainless steel. The chimney/stack should have a minimum height of 10 meters above ground level.   

2.10  Ignition Burners  

Fully packaged oil type, complete with electric ignition and flame failure controls, wired with continuous running fan and complete with all valves, fan and motor.  

Maximum rating:            at least 450kW/hour  

Burner:                            arranged for on/off operation  

Maximum consumption: at least 6 litres/hour  

Average consumption:    at least 3 litres/hour  

2.11 Afterburner  

Fully packaged oil type, complete with electric ignition and flame failure controls wired with continuous running fan and complete with all valves, fan and motor.  

Maximum rating: at least 450kW/hour  

Burner: arranged for on/off operation  

Maximum consumption: at least 9 litres/hour  

Average consumption: at least 4.5 litres/hour  

2.12 Flue gas treatment  

Should have particulate remover (scrubbers)  

2.13  Electrical Supply  

Single phase 220/240 V a.c., 50/60 Hz.