Incinerator  300 kg/hr  Burn Capacity (min. 1200 kgs. Waste Feed Capacity per day) (Power Supply 380V, 50Hz, 3Ph) 

 Incinerator  450 kg/hr  Burn Capacity (min. 1800 kgs. Waste Feed Capacity per day) (Power Supply 380V, 50Hz, 3Ph) 

 Incinerator main unit main body (primary chamber, secondary chamber, mix-combustion chamber 

 Filter Chamber 

 Chimney 

 PLC Panel 

 Oil Tank 

 Combustion burner 

 Wind Tube 

 Oil Tube 

 Filter brick 

 Ash clean tool 

 Blower 

 Furnace gate 

 One bag chamber maintenance material 

Feed Capacity 600-1200 kg per feed

Burning Rate Min. 300 kgs per hour

Burning Time per Feed 2-4 hours

Voltage 380V

Power 1.48Kw

Frequency 50Hz

Fuel Natural Gas or Diesel Oil

Fuel Mode Manual

Fuel Consumption (Oil) Max 40 kgs per hour

Fuel Consumption (Gas) Max 44 m3 per hour

Waste Combustion Chamber 2400 liters

Post Combustion Chamber 1200 liters

Oil Tank Capacity 500 liters

Chimney 10.0 M

Chamber Material Firebrick, Refractory Concrete

Max. Heat Value 340,000 Kcal per hour

Operation Technical Specification

Solid Chamber Temperature 800 Deg. C – 1000 deg. C

Gas Chamber Temperature 1000 Deg. C – 1200 deg. C

Chamber Anti-Rate 1450 Deg. C

Residency Time 2.0 Sec.

Burning efficiency >98%

Waste Lower Calorific Power 3000 Kcal