Author: admin

burner for clinical waste

MINIMUM CRITERIA FOR ENGINE OF INCINERATION
CAPACITY OF INCINERATION 30KG/ H

1. BASIC SPECS:

The incinerator for clinical waste should be assigned for the damage of all kinds of waste generated by the Facility for Wellness (waste type medical facility, facility, medical laboratory for devastating capability of 30kg/ h).

Pyrolytic gasification combustion control shall:

? Prevent development of black smoke and also dust development tine loading of waste;
? Supply normal and complete burning of the waste;
? Provide regulated guaranteeing the absence of shade, cloud of smoke or shedding odor;
? Permit restricted gas intake

The incinerator with pyrolytic combustion must have:

a. Combustor:

– – Chamber solid steel support legs sheet;
– – The cellular lining is made of refractory blocks and also a thermal insulation making certain a minimum temperature of the sheet;
– – The sole burning is made up of a refractory lining particularly created to meet the thermal, mechanical as well as corrosive liquid waste requirements and liquified glass;
– – The dimensions of the floor are geared up laterally primary air nozzles that sustain combustion;
– – The fireplace is outfitted with a mixing system of waste burning is regulated switch;
– – The recovery operation of the ashes will happen once a day line prior to starting the day’s procedure.

Structure of the refractory cellular lining:
* Insulation:
– – Operating temperature level: 1000 ° C max
– – Nature: Calcium Silicate
– – Thickness: 80 mm
* Refractory:
– – Running temperature: 1650 ° C max
– – Nature: Refractory bricks with 42 alumina – Density: 110mm

Heater burning:

– The combustion chamber is geared up with a burner to line to ensure right temperature level for the overall damage of waste combustion; – Automatic monobloc burner and flame dive furnished with a digital ignition system and also permanent air flow. Air fan: – A main air and secondary air follower gives the required oxygen delivery – There is an electric motor operated shutoff that regulates the circulation according to the combustion. – The stress of the follower is 500 mm CE to pierce the mass of
– waste throughout combustion.

b. Article – combustion chamber:

– Deal with the gas has a minimal temperature level of 1100 ° C with a minimal residence time of two secs the afterburner is to; – An additional air injection is anticipated as well as gives best oxygen material; – The heater makes sure a minimum temperature of 1100 ° C constant; – The style of this heater resembles burning burners; – The afterburner is– outfitted with accessibility doors in order to make sure normal cleaning– of dust; – The afterburner is lined with high thermal insulation with a thickness of 150 mm

c. Closet, control and also regulation: – The entire installment will adapt European standards( EU ). – The electrical power is 220V 50Hz solitary phase. – Regulatory authorities of temperature with electronic display screen:.
–? 1 to manage the temperature of the burning chamber.? 1 for regulating the temperature of the afterburner.
? The hands-on controls are provided on each thing
.

2. PRODUCT MEASUREMENTS

Summary Dimensions. Destructive ability 30 Kg/ hr. Procedure 12h/24, 6d/ 7. Gas diesel oil. Smokeshaft Elevation: 5m, Diameter: 280mm.
Quantity of combustion

chamber Burning: 0.3 m3.
Blog post burning: 0.2 m3. Combined burning chamber: 0.3 m3.
‘TEMPERATURE LEVELS:. Combustion. Afterburner. 900 ° C. 1100 ° C. POWER BURNER. Burning. Afterburner

0.11 KW.
0.11 KW0

Follower power 0.37 kW

Read More

waste burner manufacturers from china

Incinerate: medical waste and also basic waste Capacity to melt waste:
400-500kg/ hr.
Gas: Diesel.
Gas Intake: 10 liters/hr optimum.
Incineration temperature: 950-1300 degrees centigrade.
Case: thick (minutes 5mm) stainless steel covering as well as totally protected to.
hold up against sea humidity Voltage 220/240v or 380/415V Regularity 50Hz.
high-capacity, powerful, European Criterion burner, perfect for high volume incineration, with integral after-burner for greater performance as well as exhausts manage.
Waste Type as well as Melt Rate.
Made particularly for usage by fowl farmers,.
lamb farm owners, abbatoirs as well as for pet.
cremation. The burner will shed up to 50kg of.
waste per hour (as much as 150kg shed.
Construction.
Mild steel welded construction containing sheet steel.
as well as structural area supports.
Cellular lining.
Monolithic high quality refractory concrete with high grade insulation backing.
Heaters.
Totally automatic, high-efficiency burners with digital ignition, flame acknowledgment as well as combustion control gadgets fitted.
Loading– Ash removal.
Hands-on ash elimination from the key chamber. (Ash doors are readily available on demand).
Outside coating.
Multi-coat premium quality, high-temperature aluminium enamel leading coat paint, completed in silver.
Control.
Fully automatic sequential control given by interior.
waste burner producers from china, PLC system providing control of:.
1. Additional chamber pre-heat.
2. Shed cycle (variable).
3. Cool cycle.
Fuel Options.
Diesel, LPG, Natural or Bio Gas.
Normal Fuel Consumption.
Diesel: 8/ 10 litres per hr.
Fluid Propane Gas: 6/ 8 litres per hour.
Gas: 7/ 9 Nm3 per hour.
Electrical supply.
240volt 16 amp.
Secret Specifications.
Chamber Quantity 2.38 m3:.
2.2 m (l) x 0.9 m( w) x 1.2 m( h).
Lots Capacity approximately 1000kg.
Tons Approach Top. · Kind: Pyrolytic

· Use: For medicines

· With Chassis to be Placed in truck/lorry

· May have a main as well as additional combustion chamber

· Should have a dilution chamber

· Capability: 100 Kgs per hour

· Source Of Power: Diesel or Natural Gas or Liquified Gas

Read More

clinical waste diesel incinerator

medical waste diesel burner Burning Price:47.5–– 50kg/hour.
Minimum Operating Temperature:850 o C( key combustion).
Optimum Operating Temperature level:1450 oC( Afterburner chamber).
Secondary Burning Capacity: Compulsory.
Thickness Insulation:20 mm High.
Refractory Casting: Minimum 65mm.
Heavy duty refracting lining to withstand:1500 oC.
Typical burn out time: maximum:3 humans resources.
Fuel type: Diesel.
Gas Consumption in L/hr:7.5 to 9.
Home time in additional chamber:2 sec.
Residue ash blog post 100kg: Max 3.8 kg.
Gadget for protecting against transmittable spatter and/or cross-contamination by securely sanitizing needles, rings, and so on by infrared warmth.
Electric characteristics.
1) A 120V, 60Hz mono-phase electrical source with line connection plug NEMA 5-15 kind.
2) Protections against over-voltage and over-current line conditions.
3) Compliance with applicable Haitian standards as well as regulations.

Operational qualities.
4) Rapid full sterilization in around 5-7 s.
5) Totally isolated quartz/ceramic tube, to provide security for the individual (no open flame).
6) Functioning temperature level around 820 ° C.
7) Mounted on a steady base, as per instance below.

Read More

clinical waste burner

medical waste incinerator: medical waste and general waste
Capacity to burn waste: 400 — 500 kg/hr
Fuel: Diesel
Fuel Consumption: 10 litres/hr maximum
Incineration temperature: 950 – 1300 °c
Casing: thick (min 5 mm) Stainless steel casing and fully
insulated to withstand sea humidity
Voltage: 220/240 V or 380/415V
Frequency: 50 Hz
Feeding: automatic
Ash 1 leftovers removal: Automatic
Fuel gas filtration system: Yes
Warranty: 12 months
Staff training: Operator & Maintenance staff
Operation and service manuals: 3 sets each
Especifica??es Gerais     6 mm plate steel sheel construction
11cm 1400°C refractory Liner
temperature controlled Burners
secondary combustion burners
interlock switch on load doors
separete ash door
one secondary residence @ 1000°C
400°C silicone Based finish paint
alloy temperature sensor
factory wired and tested
Capacity    20kg/hr
primary Chamber    1607 L
Hearth area    1.36 aq.m
Secondary Chamber    694L
Primary burner (oil)    420.00btu
Secondary burner (oil)    900,000btu
Secondary combustion    1/6 hp
Exhaust stack    46cm x 6m
Electrical service     220/50
System weight    5,700kg
Dimension “D”    152cm
Doad port height e    60x60cm
Ash port height e    36x36cm
General Specifications    6mm plate steel sheel construction
11cm 1400 ° C refractory liner
temperature controlled Burners
secondary combustion burners
interlock switch on load doors
separete ash door
one secondary residence @ 1000 ° C
400 ° C silicone based paint finish
alloy temperature sensor
factory wired and tested
Capacity    20kg/hr
primary Chamber    1607 L
Hearth area    1:36 aq.m
Secondary Chamber    694L
Primary burner (oil)    420.00btu
Secondary burner (oil)    900,000 btu
Secondary combustion    1/6 hp
Exhaust stack    46cm x 6m
Electrical service    220/50
System weight    5.700 kg
Dimension “D”    152cm
Doad port height and    60x60cm
Ash port height and    36x36cm
medical, hospital, veterinary and industrial wastes by medical waste incinerator Process.
So, we’re interested with your Incinerator plants, and we’d like to get quotation and key features description of different capacities of your Incinerator plants, concerning: small models (5 – 25 kg/hr); medium models (25-50 kg/hr) and big models (50-100 kg/hr) and plus.

Read More

medical waste burners suppliers

chemical representatives to be made use of:
10% heptyl (unsymmetrical dimethylhydrazine) water solution,
heptyl (unsymmetrical dimethylhydrazine) vapour with 0.8 to 1.0 kg/m3 concentration,
10% azotic (nitric) acid water remedy,
azotic (nitric) acid vapour with focus up to 1.1 kg/m3;
2. neutralization approach: thermal decay;
3. neutralization temperature level: +800? C to +1200? C;
4. performance:
? vapour ability: 70 to 200 m3/h,
? water option ability: 50 to 500 l/h;
5. inlet stress: as much as 2 bars;
6. automatic control system;
7. total measurements shall allow for placing the unit on a car framework.
clinical waste burners producers General Specs
6mm plate steel sheel construction
11cm 1400 o C Refractory L iner
Temperature regulated Heaters
Additional combustion Heaters
Interlock Turn On Load Doors
Separate Ash Door
One 2nd secondary Home @ 1000 o C.
400 ° C Silicone Based Paint Complete.
Alloy Temperature Sensing Unit.
Factory wired as well as examined.
Capacity-20 kg/ human resources.
Primary Chamber-1607 L.
Hearth Area-1:36 sq. m.
Second Chamber-694 L.
Primary Burner (oil) -420,000 btu.
Secondary Heater (oil) -900,000 btu.
secondary Combustion-1/ 6 hp.
Exhaust Stack-46cm x 6m.
Electrical Service-220/ 50.
Weight System-5.700 kg.
Measurement “D” -152 cm.
Tons Port Elevation- 60x 60 cm.
Ash Port Elevation -36 x 36 cm

Read More

health center incinerator manufacturers

The Incinerator Plant is outcome wastes incineration from Different petrochemical devices. In this job we wish to blaze all output wastes from petrochemical devices and additionally created high pressure steam from burner plant warmth created.
In the beginning outcome waste from petrochemical collects and also moves to transit and also arranging facility in various types. Input feeds of burner plant are received below table:

health center incinerator suppliers, Waste streams of petrochemical unit collect and also keep en route and Arranging Facility.
En Route and Arranging Center one laboratory need to be considered.
In this facility, waste will be identified in 2 groups:
–– Improper for burning
–– Appropriate for burning
Unsuitable waste for burning can be separated into the 4 classifications:
–– Buried materials
–– Materials (wastes) that require to be stabilized prior to hidden
–– Materials (wastes) that can be offered.
–– Wastes that can be gone back to petrochemical.
Appropriate wastes are identified right into both classifications:
–– Input wastes to rotating kiln, contain solids and also waste liquids.
–– Input wastes to fixed kiln, include clean fluids and also gasses.
All strong wastes must be transferred to storage space pit from Transportation as well as Sorting. Solid wastes storage space pit is input of rotary kiln.
All fluid wastes need to be kept and maintained in Transit as well as Arranging. All storage as well as stablizing tools or center have to be taken into consideration. Storage space as well as stabilization tools (facility) consist of:
Tanks, Pumps (Transfer, Loading & & Unloading), Agitator (Mixer), Blanketing System, Flare system, Instrumentation as well as Control Solution, and so on
. Storage and stablizing capacity need to be taken into consideration based on worst instance (shut down).
Typically incinerator plant contains two similar trains (capacity of each train is 100%). Each train consists of a rotary kiln as well as a fixed kiln.

Read More

chinese burner suppliers

In a simple design with a metal steel drum electric. including:
A cage for receipt of biomedical waste;
A combustion chamber with fireplace with a filter to retain ashes;
A cover;
An air supply;
A turbine  allowing the supply of the air.
Combustion temperature: 1800 ° C. Compliance with European standards.
Comes with all necessary accessories
Supply of incinerator model PDR-18 with:

·        Capacity 100 kg/hr of waste containing up to 85% moisture

?      Two combustion chambers

·        Two fully automatic, oil fired, pressure jet burners

·        Panel board

·         Diesel tank of capacity 250 It. with 2 diesel pipelines, filter and valve.
Type: for animals waste
Capacity: 30 kg per hours for a maximum load of 120 kg.
GLP Gas
Voltage: 110V-120V
Semiautomatic control board
Stainless steel chimney, 3.5 meters above the incinerator.
High temperature painting for all the incinerator.
Front door for loading and unloading.
Fuel    Diesel Oil 8/ kerosene
Capacity (m3)    0.57
Ave Capacity    50 kg per hour
Ave time for Burnout     5 hrs
External Dimensions
Length    2000mm
Width    1100mm
Height including flue    3500mm
Door opening
Internal Dimensions
(primary chamber)
Length    1200mm
Width    620mm
Height     660mm
Operation
Min. operating temperature    9500C
Max. operating temperature    13200C
Residency time in second chamber    2.0 seconds
Weight    1850kgs
Ancillaries
Operating and maintenance manuals
Recommended Spare list
300 liter fuel tank
Plant burning rate – 100kg/hr

Fuel – Diesel oil   – 35 sec Redwood

Overall dimensions are as follows:

Width    2261mm

Length  3264mm

Chimney Diameter  –  390mm

Chimney Height      –  8000mm
chinese incinerator manufacturers, We process 8-10 ton waste of sheep carcass and its byproduct per day. We are looking for the equipment: combustion burners(combined fuel supply:natural gas and diesel),control panel and filter system. The diameter of the incinerator is 20 cm. Lower calorific power of the waste is 4KW/KG. Heating power 4000KW

Read More

clinical waste incinerator china

medical waste incinerator china, Design, supply and manufacture ex works of one Surefire Manual Load TS50/1 Medical/General waste incinerator as detailed below: –

·         Waste type: Mixed type o,1,2,3,&4 hospital/clinical bio hazard waste

·         Waste density: 125 to 350Kg/M3

·         Waste CV: 4000 KCAL/kg

·         Moisture content: 10-25%

·         Estimated ash residue: 5-10%

·         Nominal capacity: 30Kg/hour batch load

·         Secondary chamber: 0.5 second @ 850oC
·         Compact laboratory style

·         Two combustion chambers

·         Ecologically friendly

·         Up to 50kg of waste / hour

·         To be used for animals

Read More

pet waste incinerator manufacturer

Technical requirements for burning device, animal waste incinerator supplier
1. 2 systems are called for to be mounted in the south of the Kingdom of Saudi Arabia. The two systems will be utilized by personalized authority to burn different sort of drugs. All demand devices need to be provided.
2. Warranty: booth systems need to be given with 3 years warranty from the date of approval. All required extra components, preventative upkeep repair and also restorative upkeep need to be included in the cost as well as provided to the client.
3. All required electric as well as water links should be offered.
4. Both systems have to be of premium quality and must be environmental friendly.
5. The capacity of each system must be up to 100 kg/hr.
6. The system has to have automated feeding.
7. Each system must includes two burning rooms, one main space for burning the medication and also one more space for burning the gases that emit as a result of main burning.
8. The oven should be constructed from steel that is corrosion resistance and with thickness not less than 6 mm.
9. Each system should be of high reliable in shedding various sort of medicines, and also ought to have 99.9% effectiveness for burning organic products.
10. Waste products need to not exceed 5%.
11. System needs to have automatic ignition system.
12. System needs to utilize diesel (HSD) as fuel and ought to not consume more than 8 to 10 lt/hr.
13. Each system ought to be given with fuel storage tank of dimension appropriate to run the system for one complete day.
14. The temperature level in the primary room should be 850 C ± 50 C. the system need to additionally be qualified to operate as much as 1050 C ± 50 C. the system should can continues operation as well as should be supplied with concrete layer insulator with appropriate density.
15. Oven should be provided with warm insulator to permit easy operation.
16. Gas ought to stay in the additional area for not greater than 1.5 second.
17. The main burning area must contend least 2 heaters.
18. The second burning area need to have one heater.
19. Each system must have doors for ash, leave for air to the smokeshaft and also windows to allow looking inside and for maintenance.
20. Each system must have filtering system for gas handling with 2 tanks utilizing average water. Each water container must have capability of 1000 lt and ought to be repaired to the system as well as offered with water degree indication.
21. Each system must have special innovation for separating midsection products and also humidity after gas processing.
22. Each system needs to have cooling down ability after procedure.
23. Each system m must be offered with exhaust pipe with 250 mm diameter and also 10 m high. The base of the exhaust system ought to be 1000 mm. The exhaust pipe must be 6 mm as well as needs to be supply with heat insulator. The exhaust system should be provided with pressure sign. It ought to additionally offer with ladder and Lightning Arrestor.
24. Electric power: need to be 220 volt, 3 phase, 60 Hz, as well as the motor must not be less than 15 HP.
25. Each system must be given with control panel and also indicators and needed security devices and alarm. The control panel ought to reveal at least temperature level in both the key and additional areas and also injectors of the filters and also load.
26. Each system ought to be offered with security system for any break down or defect of any type of part of the system.
27. The complying with personal protective tools have to be provide:
a.Heat immune garments for 20 individuals.
b.Heat resistant goggles for 20 persons.
28. All elements of each system must be repainted with silver color that is heat resistant.

Read More

affordable incinerators

RECYCLABLE WASTE PLASTIC (NON-PVC) 218,693
CARDBOARD 85,046
PAPER 4,956
PVC 15,115
HAZARDOUS WASTE MEDICAL WASTE 1,084
SOLID WASTE CONTAMINATED WITH HYDROCARBONS 300,680
USED ENGINE OIL FILTERS 85,423
HYDROCARBON-CONTAMINATED DIRTS 88,680
COMMON WASTE FIBERS 14,078
USED AIR FILTERS (AUTOMOTIVE AND ALSO SIMILAR) 23,149
INDIVIDUAL PROTECTIVE DEVICES (PPE), INCLUDING INFECTED CLOTHING AND ALSO SIMILAR PARTICLES 130,861
Pig corpses/ roaming pet dogs and also bigger pet carcasses economical incinerators ––.
Lots ability in the variety of up to 300 kg/ Melt rate approx. 50 kg per hour

Temperature Controlled Heater. Burners to be made to meet the Norms of Pollution Control. Modern technology: Heavy-duty covering, to be a top quality, rugged, dependable, affordable Burner with pertinent control, very easy to operate and also self-supporting. Systems to be pre-assembled, pre-piped, pre-wired & & examined prior to Transport/ Export.

Note: Comparable Modern Technology and/ or Tenderers Proposals rate.

Within the structure of an ecological tools & & technology consultation and joint buying, this Procurement/ Notary Bureau welcomes candidates for pre-qualification in the purpose of largely choosing qualified companies to bid for the above tender.
The supply will make up the special devices for efficient waste monitoring as pointed out above for a brand-new personal setting contract management firm with prepared procedures 2013 in Indonesia as well as Thailand, as well as 2015 in West & & East Malaysia to execute those expert services in order to follow the federal governments safety disposal requirements for animal waste in the region as well as to satisfy the higher technical standard in this specific area in order to secure the public and consist of infectious & & contagious infections and also pet triggered conditions. The spread of a brand-new illness of pigs, likewise the ‘‘ Nipah Infection Illness’, first noticeable in 1998 in S.E.Asia, which causes illness and also fatality in both humans as well as pigs, is on the rise once again; as well as the premature death of plants and also boars was recorded in pig farms in Malaysia as well as other locations in S.E. Asia.

Read More