inciner

Mobile Cremation Devices

Design

CA-200

Image

Burning Rate

Ordinary 100 kgs/hour

Key Burning Chamber

2000 Liters

Additional Burning Smokeshaft

Yes

Feed Mode

Guidebook

Voltage

220V

Power

3.0 Kw

Fuel Kind

Diesel Oil

Burner

Italy Original

Oil Usage (Diesel Oil)

Typical 53 kg/hour

Interior Dimensions

230 x 100 x 90cm (primary chamber)

External Measurements

290 x 200 x 170cm (key chamber)

Temperature Monitor

Yes

Oil Container Capacity( if oil fuel)

500 Liters

Door Opening

90 x 90cm

Smokeshaft Size

5.0 Meters

Chimney Type

Stainless Steel

Devices Gross Weight

9000 kgs( with container)

Procedure Technical Specifications

Paimary Chamber Temperature

800 ℃–– 1000 ℃

Second Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Efficiency

> 98%

Waste Lower Calorific Power

3000Kcal


Mobile crematorium 
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-22

Read More

Incinerator for medical facility waste monitoring

Burner for healthcare facility waste monitoring with the adhering to attributes:

– In high temperatures (pyrolytic burner 2 chambers with temperatures ranging from 950 º C to 1320 º C;

– Capacity to damage of 400 to 600kg per hr;

– Efficient in destroying microbes;

– Drain ash;

– Drain needle as well as glass crusher;

– Patio with tap water for hand cleaning and decontamination;

– Observe the problem of environmental top quality criteria, discharges fluent as well as policy on the issue of waste; mount large incinerator to among the largest veterinary health center in KSA so if you will certainly support us with one system (large incinerator) and ecological with onsite training, the ability for the device is 2000 Kg for cattle, equines and also farm animals additionally suitable to all animal waste kinds, we require it diesel fired. OES-Industrial MultiWaste Incinerator System (Solid/Liquid)

Extent of the Job:
Style, setup as well as commissioning of multi hazardous waste burner.
Capability: 315 KG/HOUR SOLID WASTE/ OR 200 LITRES/HOUR LIQUID WASTE (with double chamber system).
1st chamber-870 Deg.C – – 900 Deg.C.
2nd chamber-1000 deg.C– 1200 Deg.C

Resources Of The Wastes.
The following types of wastes can be dealt with by using incinerator.
a). biography medical waste/pharmaceutical waste.
b). strong chemical waste/textile markets waste.
c). liquid chemical waste.
d). dyes as well as intermediate waste.
e). natural chemical waste.
f). liquid ink waste/acidic deposit.
g). insecticides/herbicides/pesticides.
h). fungicide waste.
i). ethanolamine.
j). amino ethanol.
k). mono ethanolamine.
l). ETA, MEA waste.
m). wastes after treatment of chemicals in etp plant.
n). blended alcohol waste water.
o). alcoholic waste.
p). farming liquid chemical waste.
q). sludge mix liquid.
r). slurry/adhesive/grease/ powder finish wastes.
s). semi strong liquid chemical waste.
t). bulk completely dry chemical waste.
u). pharma chemical wastes.
v). solvent chemicals/paint wastes/used glass grains.
w). utilized tires.
x). used cotton cloths.
y). contaminated plastics/resin wastes.
Range of Work:.
Incinerate all types of liquid/solid hazardous/chemical/non contaminateds materials avaliable in the industries with appropriate scrubbing up system with common emission rates.
The twin stage incinerator aids to burn the waste in 2 stages, initially at a medium temperature of 870- 900 Deg C and also the 2nd stage at 1200 deg C.
Producing ash as well as Aeriform fumes which are treated with cyclone type damp scrubber as well as caustic scrubber to generate air with contaminants in the allowed variety as well as Non dangerous ash mainly not natural salts.

Incinerator utilities.
Burner should have complying with requirements:.
Metallic seal framework with ceramic insulation to stay clear of warm radiation and also control glowing temperature level.
Advanced gas treatment system to avoid emission of hazardous gases (rubbing system).
Reduced intake high performance compact automated burning system.
Low running and upkeep prices.
Fully automatic and also easy to operate control board.
Afterburner Preheat.
Thick refractory concrete lining ranked at 1600 C.
Solid Hearth to enable maximum Fatigue.
Large Leading opening cover for simple loading.
Wide door for ash removal.
Optional Stainless Steel Case.
Warmth recovery option

Read More

Medical Facility Waste Monitoring

Hospital Waste Management as well as Competitive prices as Pakistan is a competitive market. We have a complete setup with Office, Customer Relations, Import / Export, Biomedical Department, Application Support Department & Project Designing Department.Description        Minimum Requirements
Design standard    Multiple chamber incinerator to the design of EPA  standards, Air pollution control
Description of the Chimney    Top mounted, self supporting
Incinerator performance    150kg/hr
Refuse     Hospital waste and carcasses
Recommended Temperatures    Minimum 1000⁰C
Dimensions:
Length
Width
Height
Extra width for burners    At least 3000mm
Loading door opening    Minimum 700mm x 600mm
Hearth area    5.00square meters
Description or grate/hearth    A full hearth supplied to prevent contaminated liquids from flowing into the ash pit without being incinerated
Primary chamber volume    At least 3 cubic meters
Mixing chamber volume    At least 1 cubic meters
Settling chamber volume    At least 3 cubic meters
Weight excluding chimney    15, 000kg at manufacture
Firing tools supplied    Hoe, Poker and rakeMaterial of construction    Case – 5mm mild steel.
Bracing – Heavy angle and channel.
Hearth – 1550⁰C castable general purpose high strength, high abrasion resistant monolithic refractory concrete.
Ashing door – High grade cast iron.
Loading door – 5mm mild steel lined with 1550⁰C castable  general purpose high strength, high abrasion resistant monolithic refractory concrete.
Refractory  concrete:
Alumina content of refractory
Refractory thickness
Minimum 49%
At least 127mm.
Insulation  to walls     1000⁰C Castable insulation
Chimney stack:
Chimney
Height from base    3.5 mm mild steel
9 meters above ground level and clear the highest point of the building by not less than 3 meters
At least 560mm
At least 750Kg
Controls:
Draught

Air supply

Electric

Barometric indicator, door operated draught limiter

Built-in forced heated air ducts, primary and secondary (intensifier)
Control panel – Circuit breakers, main switch, timer, pilot lights, 2 set point pyrometer and one set point pyrometer.
Electricity supply required    415 Volts Three phase.
Auxiliary  fuel    Electrically operated only
Emission     Multiple chamber design with inbuilt emission control
Paint: Case and stack    400⁰C Heat Resistant Grey
Temperature of case    100⁰C

Read More

WASTE BROCHURES As Well As CONTAMINATED MATERIALS LIST

1 Burner 30 =KG burn/h and also it need to have a Scrubber.

2 Burner should have Electric Plastic Shredder for cutting of glass container, surange of Medication.

3 Burner need to have Electrical Car Clave or Microwave for Dis Infection independently with burner.
4 Incinerator needs to have Double Chambers initially Chamber should provided 800C temperature level as well as additional Chamber working 1200C temperature level.
5 Incinerator in out place must have a Specification to show internal temperature level of incinerator.
6 Burner has to operate in 2 systems Electric and also fuel explain in which type of fuel jobs.
Note we want it works on gasoline and also electrical also.for a small pig slaughterhouse task in Vietnam we are looking for a.
solution to ruin securely inedible and confiscated pet items.

As the slaughtered pigs are consumed by more than 90% (from hooves to.
head, blood, etc) the waste volume is fairly tiny also in.
slaughter-points with as much as 100 slaughtered pigs each day.

Although using meat and also bone meal is not banned in Vietnam the.
small quantities of waste do not seem to warrant the installment of a.
rendering system, not also of a batch stove, so incineration seems to be.
the very best option.

I wish to get even more technological details e.g. gas usage for.
blazing 100/200 kg of animal items per day as well as also the FOB.
cost of the unit.The types of waste to be treated are (after EUROPEAN WASTE BROCHURE AND CONTAMINATED MATERIALS CHECKLIST, 2002):

18 01 01 sharps (other than 18 01 03)

18 01 02 body components and organs including blood bags and also blood maintains (other than 18 01 03)

18 01 03 * wastes whose collection and also disposal undergoes special needs in order to avoid infection

18 01 04 wastes whose collection as well as disposal is not subject to unique requirements in order to protect against infection (for example dressings, cast, linen, disposable clothes, baby diapers)

18 01 06 * chemicals containing or consisting of unsafe compounds

18 01 07 chemicals besides those stated in 18 01 06

18 01 08 * cytotoxic as well as cytostatic medications

18 01 09 medications aside from those discussed in 18 01 08

18 01 10 * amalgam waste from dental treatment

Read More

dispose Medical waste IV

the incinerator can be made use of to get rid of Medical waste IV, used needles, made use of syringes, scalpels, used dressing material, individual safety devices like gown, gloves and so on truncated body parts, excreta from clients and also various other research laboratory waste.incineration devices that can handle a mix of clinical as well as contaminateds materials. The clinical wastes consist of (yet are not limited to) materials contaminated with blood, physical liquids, feces, and also human tissue/organs from surgical treatment. The dangerous compounds include (however are not limited to): xylene, toluene, chloroform, methylene chloride, trichloroethylene, acetonitrile, formaldehyde wastes, radiation treatment wastes (e.g., Chlorambucil, Cytoxin, Daunomycin, and so on) radiology wastes (e.g., glutaraldehyde), and mercury-containing compounds.includes amputated body parts, body fluids including contaminated blood, blood items, excreta from people, cultures of transmittable infections as well as various other research laboratory wastes e.t.c.
Medical might also consist of used needles, made use of syringes, made use of, expired or infected clothing products like plasters, plasters and plastics, e.t.c. The Burners ought to likewise enable disposal of other wastes created in healthcare facility environment.Technical Requirements for Portable Incinerators

The Chamber volume of around 0.37 m3 and also a.
1 combustible lots quantity (quantity of material) of.
around 0.30 m3

2 Burner power of around 189,000 kcal/hour.
Optimum Burning Temperature Level of approximately 1250

Degree Celsius.
Kind of sent out Gas: Inert as well as zero ecological air pollution effect.
Electric Power: 220V/50 or 60 Hertz

Fuel: Diesel

Electric intake of roughly: 0.35 kw/hr

Gas usage variety: 7 – – 11 ltrs/hr

Controls: Incinerator control including control panel, timer, display screen for keeping an eye on combustion temperature level, system mistake display screen, and so on
. Packaging/Installation: Burner completely set up as well as all set to be connected in power source

User’s manual: Bundle has to be given with user’s manual including described information to installment, procedure, upkeep, analysis of problem shooting signals and also contact telephones. numbers/emails of neighborhood or abroad supplier’s specialists that can be called for assistance on procedure of the devices, if required.

training guide/manual on a compact disc including a demonstration for installment, operation and also. maintenance, in addition to safety standards, etc.

Scope of Supply: Bundle needs to be supplied including. all the called for devices for installation and also must. consist of spare parts/consumables that are needed for a. one year period at a burning rate of approximately 8 hrs. daily

Guarantee must be provided for a 5-years period. beginning with the burner’s setup and. consisting of the arrangement of accessories as well as.
consumables

Read More

CONTAINERIZED BURNER FOR INCINERATING HAZARDOUS AND ALSO NON HAZARDOUS WASTES

CONTAINERIZED BURNER FOR INCINERATING HAZARDOUS AND NON HAZARDOUS WASTES (BOTH DOMESTIC As Well As INDUSTRIAL) AT A MINIMUM PRICE OF 300KG/HR WITH THE COMPLYING WITH REQUIREMENTS:

Ø PRIMARY CHAMBER VOLUME 7.2 M ³

Ø BURNING CAPACITY 300Kgs/hr.

Ø PRIMARY CHAMBER TEMPERATURE 850 ⁰ C AND SECONDARY CHAMBER TEMPERATURE LEVEL 1100 ⁰ C

Ø REFRACTORY DENSITY 225MM; REFRACTORY WITHSTAND TEMPERATURE 1400 ⁰ C

Ø RAM LOADER CAPACITY 0.75 M ³; FUNCTIONAL CYCLES EACH DAY 8-16 Humans resources.

Ø GAS DIESEL/NATURAL GAS; VARIETY OF PRIMARY BURNERS & & SCORE: 2 @ 250kw

Ø VARIETY OF SECONDARY BURNERS & & RANKING: 2 @ 400kw; ELECTRIC SUPPLY 230V 60Hz

Ø CONTAINER TIPPER, MONITORING SYSTEM, CLEANSING SYSTEM

Ø GAS CLEANING AND ALSO GAS MONITORING.MSW1000 General Medical Waste Incinerators melt price approximately 100kg/hr
A2400 Animal/ fowl Waste Incinerators burn rate as much as 200kg/hr. Laboratory waste Management system
01. Liqued water filtration system.
02. Number of laboratories – 05
03. The approximated liquid water waste – 6000 L including
a. chemicals
b. contaminants
c. Bio Hazardous products.
Temporary alloted room for filtrations system- 30×× 20.
The following need to be indicating in the biding document.
1. Technique of getting rid of treated waste water.
2. Method of disposing of the sludge.
3. To comply with ISO standard/regulations of Central Environment Authority [CEA] 4. Period for building and construction.
5. Request the cost for every thing of the project [Consultancy/designing/construction] For the whole task.
6. Guarantee period as well as maintaincne.

Read More

STRONG WASTE INCINERATOR

Primary chamber – Consists of a monolithic high grade refractory concrete with high grade insulation backing, . Utilising a refractory hearth or equivalent for continuous ash removal.

Secondary Chamber – Consists of high density, low thermal mass refractory ceramic fibre with an innovative low emissivity protective coating. bio medical waste treatment plant ( Incineration )with panel.

SOLID WASTE INCINERATOR    Feeding Capacity:    200 to 220 Kg.
Burn Rate *    60 Kg / hr
Ingredients to be burned    Cotton, Rubber, PVC Sheets, PE Gloves, Oil, Plastic Bottles, Paper etc.
Chambers *    Dual Chamber.
1: Primary Controlled Air
2: Secondary Excess Air
Temperature Monitoring    Required
Temperature Control to Primary & Secondary Chambers    Required
System Status & Alarms    Required for all necessary parameters.
Fittings & Accessories    Complete Package is required ( Including Nozzles & Flanges etc.)
Installation Requirements.    As low as possible . Almost Plug & Play type.
Dimensional Sketch, Operation & Installation Manuals.    Required
Off – Gas System    Required
Heat Insulation    Required for indoor installation
Delivery    Karachi Sea Port – Pakistan

The details of Components of incinerator is as follows:
Component Name        Features                 Range.
Primary Chamber    Temperature Required*    800 – 1000 deg C.
Heating Source    Natural Gas

Secondary Chamber    Temperature *    1100 – 1300 deg. C
Heating Source    Natural Gas + Propane or Fuel Oil as an additional source
Off – Gas Residence Time     2 Seconds.
Refractory Material    Material *    Alumina ( 56 – 80 % Pure )
Lining *    SS 316L
Life Span *    10 – 15 years.
Rating Temperature    1600 – 1800 deg. C
Media    Slightly acidic
Insulation    Material    Ceramic Fiber
Thickness    25 “ minimum
Feeding & Ash Removing     System    Air Tight ventilating locked doors ( Feeding from Top will be preferred)
Spares    Required for 5 Years trouble free operation

Read More

dual chamber incinerator

Waste calorific value: 4000KCAL/KG
Wetness Web content: 10-25%.
Nominal Capability: 50Kg/Hour batch load.
Secondary Chamber: 2 Secs @ 850degrees C.
The main combustion chamber should ensure minimal departure temperature level is not less than 850 degrees C.

INSULATION.
Calcium Silicate.
Restricting Continuous service restriction 1000 degrees C.
Thickness 25mm

THROUGHPUT.
50kg/hour at a small calorific worth of 4,000 kcal/kg as well as an average bulk thickness of 120kg/MCubed for basic waste and 160kg/MCubed for healthcare waste.All sorts of chemicals compounds (Biocides) that made use of for Oil procedure sites (water base Drilling, oil operating facilities for the corrosion and also others: The instances of the biocides are “WS-36, HAI-85M, SOFT DRINK ASH, DSMA, MICRO MATRIX, CALCIUM CARBONATE PENALTY, BARAKLEAN, GILSONITE, MIXED WASTE DIRT CHEMICALS, ZINC CARBONATE, CAUSTIC SOFT DRINK, ENVIROTHIN, BARAZAN D,. etc) as well as the materials are fluid and strong.

2. In regards to the amount of shedding the waste, maybe 200 – – 500 kg per hr.

3. Our Operational time can be in Day as well as can be at night.

4. Can you please provide me the expense of device operated with Diesel and Gas.The primary combustion chamber is the major structure of the burner, produced from light steel plate and stiffened with rolled steel sections. It is carried from the floor level on a significant steel support structure. Internally the covering is lined with calcium silicate insulation and also a warm face combination of incredibly duty brickwork or high strength castable.
The key burning chamber should make sure minimum departure temperature level is not much less than 850 ° C
. One Hands-on Lots Incinerator making up:.
·???????? Guidebook Loading door.
·???????? Horizontal strong fireplace, refractory lined main combustion chamber. Approximate dimensions 800 mm sizes x 2100mm long.
·???????? Complete sized bulk load/ash elimination door.
·???????? 1 off diesel-fired ignition heater– temperature managed.
·???????? 1 off burning air supply follower as well as distribution system, automated control.
·???????? High capability additional burning chamber with residence time not much less than 2 secs @ >> 850 ° C. ·???????? 1 off diesel-fired afterburner– temperature managed.
·???????? Control panel– automated operation.
e????? Temperature indicator key and also secondary chambers 0-1200 ° C.
e????? Refractory lined flanged smokeshaft to a height of 10M over ground degree

Read More

nanjing clover incinerator price

Huge incinerators – – INDUSTRIAL INCINERATORS – – specs below.

2.) Dimension need for the burners is 750 — — 850 kg capability

3.) The bum rate need to be 80 LL 100 kg/ hour.

4) The key chamber shouId have an operating temperature level of 900 -1200 degree C.

5) The incinerator must despise a high temperature second chamber as well as 2 second gas
retention time at 850- 1150 degree C so that it appropriates for high threat materials.

6). The incinerator must have temperature level monitoring and thermostat control for ease of
operation and also guarantee of bottom temperature to validate right procedure.

7). The burner should be capable of shedding any of the hazardous wastes listed in the
subsequent area.

8) The burner should can burning diesel oil and also need to consist of a bigger gas
tank (10-500 litres) and also generator (3 –– 40 kV )established that can be carried on the trailer with the
incinerator to make sure that the device needs no exterior electrical power supply.

9.) The burner needs to be trailer mounted so that it is a po

Contaminated materials to be Incinerated

Unsafe strong chemical:

Different types of combustible solids, made use of textiles, oil, as well as toner cartridges, chemicals
for water purification and photo consumables and plastic product, vacant
plastic/metal cans that still contain remnant unsafe material, oil absorbing.

Harmful liquid chemical:

Generally various kinds. of Acid, Paint, Varnish, Acetone, White Spirit Aromatic-less
Solvents, Artificial Liquid for Break Solutions, Aircraft De-icing Fluid, Hydraulic as well as
Compressor oil, Freon, made use of in some older refrigeration systems, Pesticide liquid/spray, air
freshen spray and various other similar chemicals.

Polluted gas:
Mostly diesel or gasoline infected by water or solvents.

Used and/or Infected oil:

Made use of electric motor oils and/or mineral oils unfit for their originally meant use. Primarily electric motor
and also transmission oil (roughly 80%) polluted by a mix of white spirit and also acetone (about 51%), hydraulic fluid (about 5%).

Infected water:

Waste oilshvater, leaches, hydrocarbons/water blends, solutions and also leachate.

Polluted soil:

Soil contaminated by oil, gas or 11 chemicals.
Contaminated soil polluted by chemicals that needs to be reused in land fill.
Polluted dirt—— treated and replaced on website.

Oil Contaminated Solids
Rags, Absorbents, Cardboard, oil and also fuel filters, air filters are rule out as harmful materials.

Electronic waste:

Waste electric or digital home appliances or settings up, including printed circuit card,
containing toxic material and/or heavy metal and/or emitting low radiation.

Utilized battery cells:

Dry battery, UPS battery or other types, unsorted waste batteries/ battery cells, having
products that are hazardouy.

Utilized lead-acid batteries:
Waste lead-acid batteries, rained/un-drained, and entire or smashed.

Harmful clinical waste:

Professional and related waste, arising from clinical, nursing or similar techniques and also waste
generated in facilities throughout the investigation or therapy of individuals (bio danger).

Ran out medications, strong:

Waste drugs, drugs and also medications, consisting of delicate medicines.

Ended drugs Iiquid:

Waste liquid pharmaceuticals, various type fluid chemicals for therapy, medical
grease, as well as paraffin based xpired medicines.

Ran out and/or infected fod:

Spoiled fresh food or unusable MRE’s (Meal Ready for Consume – – dry food)

Onsite Training and also Assem Option for Industrial Incinerators

I. The prospective buyers ought to includ 1a rate in their deal for training in a central location (Goma or
Bukavu) approximately 15 personnel in the operation and upkeep of the
devices.

Smart Ash Incinerators

1. Size requirement for the burners is that the device collaborates with a 55 gallon open finished
steel drum.
2. The system should operate wit. no gas and also use just 120V or 220V electrical energy for the blowers.
3. The system needs to can melting oil polluted wastes and also medical wastes with a dampness material of 0-15% J.
4. Each device ought to include two steel drums, to ensure that a spare drum is available.

Spare Components Choice.
If there are any type of supplier suggested spare components, that list as well as cost ought to be consisted of as a choice in the deal.

Read More

hospital burner

Supply, setup and testing of clinical waste burner with a capability of 75 kg/ hr gas (LPG) total with all accessories and also as a result with the chimney based on the technical specs as well as conditions of public wellness
make a space for the incinerator that fit 3 incinerators as in thing 3.1.1 and affixed to the burner room waste store that suit waste for a period of seven days as well as all the buildings of enhanced concrete with preparingg burner building and also shop with all the work of wiring, electrical as well as illumination systems, water supply and also sanitation
supply incinerator building as well as the waste stockroom with a fire extinguish sprinkler system relies on the source of the water from network of teh basic site, along with a fire alarm system contains sensing units for warm, smoke and this system is linked with the medical facility emergency alarm systems
Supply, setup as well as screening of the air flow system of the incinerator room and also the stockroom with fans ROOF COVERING TOP EXHAUET FOLLOWERS offering them with filters with high performance (HEPA FILTER trip to draw fans with taking the air modification price of 5 times per hr with streams and also air required grilles
Supply, setup, testing different conditioning unit for waste database DUCTED SPLIT UNITES and capability enough to maintain the interior temperature level at 14 degrees Celsius in summertime and winter
Supply, installation, screening of the cooling shop of shielded premade wall surfaces inside the waste room with a capacity of 35 cubic meters to conserve the medical waste at a temperature of no Celsius till shedding including the cooling unit and all accessories
UNSAFE wood.
play timber.
petroleum residual waste.
hydraulic hose system.
calcium hydroxide bags.
bags or wooden boxes including cyanide.
medical waste.
filters.
pharmaceuticals.
NO HAZARDOUS sawdust.
plastic.
plastic and also textil awnings.
wood.
plastic bathtubs.
rubber.
hygienic waste.
EPPs.
plastic bags.
building and construction recurring.
infected dustcloths or towels.
plastic or packaging of food.
polyestirene dishes, glasses, spoon, fork, etc.Capacity incinerator clinical waste to high burning temperature level.
With a smokeless gadget to shield the setting as well as with two combustion chambers furnished with gas burners or oil.
– burner to shed large volume items of 70 cm.
discrepancy: Automatic Control System.
– destructive capability from 20 to 30 kgs.
First-room/ Temperature = 900 ° C combustion.
Second room/ Temperature level = 1200 ° c afterburner

Read More