Tag: hazardous waste

Hiclover waste burner

Key Features:

— — Full array burner with Saved money Tiny Scale incinerator, Criterion Small-Large Scale burner,

General Municipal Solid Waste Burner, Family Pet and also Animal Cremation, Containerized Mobile Burner,

High Effective Environmental Waste Incinerator.

— Single combustion chamber, double combustion chambers, three combustion chambers and 

multi-combustion chambers waste incinerators.

— System solutions for medical waste environmental.

— High burn rate, from 5kgs to 1000kgs per hour.

— New Design for pet animal cremation business.

— HICLOVER, trusted partner with years of experience.

HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental 

protection, animal and pet cremation engineering, other municipal solid waste incineration project.

We supply solitary combustion chamber, double burning chambers, three burning chambers and

multi-combustion chambers waste burners for lab, facility, hospital, medical center, health

clinical waste destruction with medical non reusable, organic waste, clinical plastic waste, hazardous waste,

red bag waste, needle disposal, gauze and plasters, sealed sharp containers, pathological waste, trace-chemotherapeutic wastes, and so on.

Our range of incinerators provide for small to big range pet cremation associated organizations, such as fowl ranches,

cattle ranches, lamb farms, pig farms, stables, kennels, testing lab, catteries, animal crematoriums.

The incinerator burn waste in primary combustion chamber and burn the smoke from primary combustion chamber 

again to make sure environmentally friendly with no black smoke, smelless, reduce pathogenic bacteria infection.

System solutions for medical waste environmental, including waste incineration, smoke emission treatment, 

high-temperature sterilization, ultraviolet sterilization lamp, waste shredder, needle destroyer, medical waste 

package, sharp containers, etc.

The pet cremation equipment humanized design with movable platform, small space covers for modern pet 

cremation business owner all over the world.

The containerized mobile incinerator mounted in ISO container before leave factory, pre-installation, no 

incineration house build construction, movable by truck and ultraviolet lamp sterilization inside.

HICLOVER is growing brand for environmental protection field, and market share with most of Africa, 

Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner 

for governmental organizations, non-profit organizations, international contractors, logistics organizations, 

military, pet cremation business owners, etc. We have export experience more than 40 countries, including 

war zone like Iraq, Afghanistan, Somalia, South Sudan.

We are china burner manufacturer, professional as well as exporter. Manufacturer make reasonable cost for

incinerator consumer, supply medical burner, medical facility burner, animal incinerators, hog burners,

family pet cremation devices, tiny burner, family pet incinerator, animal incinerator, portable incinerator, little

pet incinerator, contagious waste pyrolysis equipment, lab incinerator. HICLOVER help client

reduce purchase budget, custom-made made feature, top quality items and friendly solution.

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-02-12

Read More

Incinerator for medical facility waste monitoring

Burner for healthcare facility waste monitoring with the adhering to attributes:

– In high temperatures (pyrolytic burner 2 chambers with temperatures ranging from 950 º C to 1320 º C;

– Capacity to damage of 400 to 600kg per hr;

– Efficient in destroying microbes;

– Drain ash;

– Drain needle as well as glass crusher;

– Patio with tap water for hand cleaning and decontamination;

– Observe the problem of environmental top quality criteria, discharges fluent as well as policy on the issue of waste; mount large incinerator to among the largest veterinary health center in KSA so if you will certainly support us with one system (large incinerator) and ecological with onsite training, the ability for the device is 2000 Kg for cattle, equines and also farm animals additionally suitable to all animal waste kinds, we require it diesel fired. OES-Industrial MultiWaste Incinerator System (Solid/Liquid)

Extent of the Job:
Style, setup as well as commissioning of multi hazardous waste burner.
Capability: 315 KG/HOUR SOLID WASTE/ OR 200 LITRES/HOUR LIQUID WASTE (with double chamber system).
1st chamber-870 Deg.C – – 900 Deg.C.
2nd chamber-1000 deg.C– 1200 Deg.C

Resources Of The Wastes.
The following types of wastes can be dealt with by using incinerator.
a). biography medical waste/pharmaceutical waste.
b). strong chemical waste/textile markets waste.
c). liquid chemical waste.
d). dyes as well as intermediate waste.
e). natural chemical waste.
f). liquid ink waste/acidic deposit.
g). insecticides/herbicides/pesticides.
h). fungicide waste.
i). ethanolamine.
j). amino ethanol.
k). mono ethanolamine.
l). ETA, MEA waste.
m). wastes after treatment of chemicals in etp plant.
n). blended alcohol waste water.
o). alcoholic waste.
p). farming liquid chemical waste.
q). sludge mix liquid.
r). slurry/adhesive/grease/ powder finish wastes.
s). semi strong liquid chemical waste.
t). bulk completely dry chemical waste.
u). pharma chemical wastes.
v). solvent chemicals/paint wastes/used glass grains.
w). utilized tires.
x). used cotton cloths.
y). contaminated plastics/resin wastes.
Range of Work:.
Incinerate all types of liquid/solid hazardous/chemical/non contaminateds materials avaliable in the industries with appropriate scrubbing up system with common emission rates.
The twin stage incinerator aids to burn the waste in 2 stages, initially at a medium temperature of 870- 900 Deg C and also the 2nd stage at 1200 deg C.
Producing ash as well as Aeriform fumes which are treated with cyclone type damp scrubber as well as caustic scrubber to generate air with contaminants in the allowed variety as well as Non dangerous ash mainly not natural salts.

Incinerator utilities.
Burner should have complying with requirements:.
Metallic seal framework with ceramic insulation to stay clear of warm radiation and also control glowing temperature level.
Advanced gas treatment system to avoid emission of hazardous gases (rubbing system).
Reduced intake high performance compact automated burning system.
Low running and upkeep prices.
Fully automatic and also easy to operate control board.
Afterburner Preheat.
Thick refractory concrete lining ranked at 1600 C.
Solid Hearth to enable maximum Fatigue.
Large Leading opening cover for simple loading.
Wide door for ash removal.
Optional Stainless Steel Case.
Warmth recovery option

Read More

CONTAINERIZED BURNER FOR INCINERATING HAZARDOUS AND ALSO NON HAZARDOUS WASTES

CONTAINERIZED BURNER FOR INCINERATING HAZARDOUS AND NON HAZARDOUS WASTES (BOTH DOMESTIC As Well As INDUSTRIAL) AT A MINIMUM PRICE OF 300KG/HR WITH THE COMPLYING WITH REQUIREMENTS:

Ø PRIMARY CHAMBER VOLUME 7.2 M ³

Ø BURNING CAPACITY 300Kgs/hr.

Ø PRIMARY CHAMBER TEMPERATURE 850 ⁰ C AND SECONDARY CHAMBER TEMPERATURE LEVEL 1100 ⁰ C

Ø REFRACTORY DENSITY 225MM; REFRACTORY WITHSTAND TEMPERATURE 1400 ⁰ C

Ø RAM LOADER CAPACITY 0.75 M ³; FUNCTIONAL CYCLES EACH DAY 8-16 Humans resources.

Ø GAS DIESEL/NATURAL GAS; VARIETY OF PRIMARY BURNERS & & SCORE: 2 @ 250kw

Ø VARIETY OF SECONDARY BURNERS & & RANKING: 2 @ 400kw; ELECTRIC SUPPLY 230V 60Hz

Ø CONTAINER TIPPER, MONITORING SYSTEM, CLEANSING SYSTEM

Ø GAS CLEANING AND ALSO GAS MONITORING.MSW1000 General Medical Waste Incinerators melt price approximately 100kg/hr
A2400 Animal/ fowl Waste Incinerators burn rate as much as 200kg/hr. Laboratory waste Management system
01. Liqued water filtration system.
02. Number of laboratories – 05
03. The approximated liquid water waste – 6000 L including
a. chemicals
b. contaminants
c. Bio Hazardous products.
Temporary alloted room for filtrations system- 30×× 20.
The following need to be indicating in the biding document.
1. Technique of getting rid of treated waste water.
2. Method of disposing of the sludge.
3. To comply with ISO standard/regulations of Central Environment Authority [CEA] 4. Period for building and construction.
5. Request the cost for every thing of the project [Consultancy/designing/construction] For the whole task.
6. Guarantee period as well as maintaincne.

Read More

nanjing clover incinerator price

Huge incinerators – – INDUSTRIAL INCINERATORS – – specs below.

2.) Dimension need for the burners is 750 — — 850 kg capability

3.) The bum rate need to be 80 LL 100 kg/ hour.

4) The key chamber shouId have an operating temperature level of 900 -1200 degree C.

5) The incinerator must despise a high temperature second chamber as well as 2 second gas
retention time at 850- 1150 degree C so that it appropriates for high threat materials.

6). The incinerator must have temperature level monitoring and thermostat control for ease of
operation and also guarantee of bottom temperature to validate right procedure.

7). The burner should be capable of shedding any of the hazardous wastes listed in the
subsequent area.

8) The burner should can burning diesel oil and also need to consist of a bigger gas
tank (10-500 litres) and also generator (3 –– 40 kV )established that can be carried on the trailer with the
incinerator to make sure that the device needs no exterior electrical power supply.

9.) The burner needs to be trailer mounted so that it is a po

Contaminated materials to be Incinerated

Unsafe strong chemical:

Different types of combustible solids, made use of textiles, oil, as well as toner cartridges, chemicals
for water purification and photo consumables and plastic product, vacant
plastic/metal cans that still contain remnant unsafe material, oil absorbing.

Harmful liquid chemical:

Generally various kinds. of Acid, Paint, Varnish, Acetone, White Spirit Aromatic-less
Solvents, Artificial Liquid for Break Solutions, Aircraft De-icing Fluid, Hydraulic as well as
Compressor oil, Freon, made use of in some older refrigeration systems, Pesticide liquid/spray, air
freshen spray and various other similar chemicals.

Polluted gas:
Mostly diesel or gasoline infected by water or solvents.

Used and/or Infected oil:

Made use of electric motor oils and/or mineral oils unfit for their originally meant use. Primarily electric motor
and also transmission oil (roughly 80%) polluted by a mix of white spirit and also acetone (about 51%), hydraulic fluid (about 5%).

Infected water:

Waste oilshvater, leaches, hydrocarbons/water blends, solutions and also leachate.

Polluted soil:

Soil contaminated by oil, gas or 11 chemicals.
Contaminated soil polluted by chemicals that needs to be reused in land fill.
Polluted dirt—— treated and replaced on website.

Oil Contaminated Solids
Rags, Absorbents, Cardboard, oil and also fuel filters, air filters are rule out as harmful materials.

Electronic waste:

Waste electric or digital home appliances or settings up, including printed circuit card,
containing toxic material and/or heavy metal and/or emitting low radiation.

Utilized battery cells:

Dry battery, UPS battery or other types, unsorted waste batteries/ battery cells, having
products that are hazardouy.

Utilized lead-acid batteries:
Waste lead-acid batteries, rained/un-drained, and entire or smashed.

Harmful clinical waste:

Professional and related waste, arising from clinical, nursing or similar techniques and also waste
generated in facilities throughout the investigation or therapy of individuals (bio danger).

Ran out medications, strong:

Waste drugs, drugs and also medications, consisting of delicate medicines.

Ended drugs Iiquid:

Waste liquid pharmaceuticals, various type fluid chemicals for therapy, medical
grease, as well as paraffin based xpired medicines.

Ran out and/or infected fod:

Spoiled fresh food or unusable MRE’s (Meal Ready for Consume – – dry food)

Onsite Training and also Assem Option for Industrial Incinerators

I. The prospective buyers ought to includ 1a rate in their deal for training in a central location (Goma or
Bukavu) approximately 15 personnel in the operation and upkeep of the
devices.

Smart Ash Incinerators

1. Size requirement for the burners is that the device collaborates with a 55 gallon open finished
steel drum.
2. The system should operate wit. no gas and also use just 120V or 220V electrical energy for the blowers.
3. The system needs to can melting oil polluted wastes and also medical wastes with a dampness material of 0-15% J.
4. Each device ought to include two steel drums, to ensure that a spare drum is available.

Spare Components Choice.
If there are any type of supplier suggested spare components, that list as well as cost ought to be consisted of as a choice in the deal.

Read More

animal burners up for sale

SMART ASH INCINERATORS FOR THE DISPOSAL OF HAZARDOUS WASTE
? Amount: 20 units
? The Burner works with a 55 gallon open finished steel drum
? The unit operates without fuel and utilized only 120v or 220v electrical power for the blowers
? Unit can melting oil infected waste and also medical wastes with a moisture material of 0 to 15%.
? Each unit is provided with 2 steel drums, to make sure that a spare is readily available.
? Each unit to be provided with suggested spare components.
? Service warranty– minimum one year from invoice as well as approval.
? User’s manual to be offered in French and English

HAZARDOUS WASTE TO BE INCINERATED

Dangerous Solid Chemicals.
Different sorts of flammable solids, made use of textiles, oil and toner cartridges, chemicals for water filtration and also photo consumables, and plastic product, empty steel/ plastic cans that still have residues of dangerous products, oil absorptive

Unsafe Fluid Chemicals.
Mostly various types of Acid, Paint, Varnish, White Spirit, Aromatic-Less Solvents, Artificial Fluid For Brake Solutions, Aircraft De-icing Liquid, Hydraulic And Also Compressor Oil, Freon used in some older refrigeration systems, Pesticide Liquid/Spray, Air Refresh Spray and various other comparable chemicals

Infected Gas.
Mostly diesel or gas contaminated by water or solvents

Used and/or Polluted Oil.
Utilized electric motor oils and/or mineral oils unfit for their originally meant usage. Generally motor/gear box oil (approx. 80%) infected by a combination of white spirit and also acetone (approx. 5%) hydraulic liquid (approx 5%)

Contaminated Water.
Waste oils/water, leaches, hydrocarbons/water mixtures, emulsions and also leachate

Infected Dirt.
Dirt polluted by oil gas of chemicals,.
Soil contaminated that has to be reused in landfill,.
Soil dealt with as well as changed on site

Oil Polluted Solids.
Cloths, absorbents, cardboard, oil and fuel filters, air filters are not considered as unsafe products

Electronic Waste.
Waste electrical or digital appliances or settings up, including printed circuit boards having harmful product and/or hefty metal and/or discharging reduced radiation

Utilized Battery Cells.
Dry battery, ups battery or other kinds unsorted waste batteries/battery cells, having products that are harmful

Used Lead Acid Batteries.
Waste lead acid batteries, drained/ un-drained as well as whole or smashed

Hazardous Medical Waste.
Scientific as well as associated waste emerging from clinical, nursing or similar methods and waste produced in facilities during the examination or treatment of people (biography threat)

Ended Medicines Strong.
Waste drugs, drugs as well as medications, consisting of sensitive medicines

Expired Medicines Liquid.
Waste liquid pharmaceuticals, various type fluid chemicals for treatment, medical oil as well as paraffin based ended medications

Ended and/Or Contaminated Food.
Spoiled fresh food or pointless dish prepared to eat meals (MRE’s) completely dry food

Read More

laboratory burner

the whole carcass of animals (cattle, horses,
Sheep, pigs, and so on), in addition to naturally hazardous waste
Products in the gas oven.
? Opening up Doors – – the closure and also addiction automatic system,
Which are taken care of from another location by the operator.
? made to work in long mode as well as quick
Activity (Flying Start EP – – i). –? Totally mobile – installed on wheeled chassis.
Also throughout the procedure. Incinerators need to be provided.
As common devices an unique truck

air retention for at the very least 2 secs at a temperature of less than 850C, the combustion.
In order to achieve the appropriate impact.
? should be a two-chamber burners, main as well as additional.
Gas ovens.
? The waste items to reduce the preliminary quantity.
Feasible to lessen (about 5% clean and sterile ash.
Form).

Burners should be offered in the fuel tank (diesel ).
? The minimum ability of the pet carcass incinerator.
The devastation of 1000 kg/ hr. Burner capability is calculated.
8MJ/kg- product and also 60 % humidity.
? It has to be feasible to use the burner +40.
C to – – 15 0C research laboratory incinerator.
Temperature as well as 5% – – 95 % – of moisture conditions.
? PLC controller as well as a built-in temperature panelita full.
Automatic control, a control computer system, which is kept.
Info on the variant of temperature level relative to time as well as.
Graphic photos.
? must have gas with automated control and malfunction.
Discovery system.
? the capacity to pre- warm-up, body waste burning on as well as off.
Consistency is independent of the first and secondary chambers.
? guaranteeing the incinerator with electrical energy, it.
Must be installed on the generator.
? tidy the burner ought to be easy tools,.
Without utilizing any type of additional tools

Read More

tiny scale clinical waste burner

Hazardous and also unsafe wastes,
Clinical pharmaceutical as well as friendly liquids Wastes
Domestic trash
Electric and digital wastes
Hazardous waste
In General, all kind of wastes and also garbages
Ability 50-60Kg/ h

Combustion supporting materials
Coal oil, diesel oil

Temperature level inside
800-10000C

1000-12000C

Burning effectiveness
> 98%

Power intake
1.3 KW

Sound
< 78dB

Index of let smoke and waste gas
Ringelman’s smoke index < degree 1

Smoke focus
Oil
45.5

( mg/m3 ).
Gas.
25.5

( mg/m3 )

SO.
Oil.
0.176.
Gas.
0.065

NOX.
Oil.
0.031.
Gas.
0.038

H2S.
Oil.
0.016.
Gas.
0.008

CO
.
Oil. 8.32.
Gas.
35.64

small scale medical waste incinerator Demands.
Incombustible and also eruptive products not admitted

Process way.
2 burning closets (dampness drying, heat dirt elimination)

Combustion/ Heater.
Top quality made in Italy

Blower.
Good Quality made in China

Control Electrical.
Top quality made in China

Ability 50 Kg/h

Functioning Voltage.
220 V

Power.
1000 W

Applied For.
200 beds

Input Fashion.
Hands-on

Medical Burner, 24 kg/hr.
Medical Burner, 24 kg/hr including panel board, controls as well as accessories.
Heater entrance.
Chimney.
Blower.
Combustion heater

Medical Incinerator, 12 kg/hr.
Medical Burner, 12 kg/hr including panel board, controls and also accessories.
Furnace gateway.
Chimney.
Blower.
Burning burner

Medical Incinerator, 6 kg/hr.
Medical Burner, 6 kg/hr consisting of panel board, controls as well as devices.
Heater gate.
Chimney.
Blower.
Burning heater

Read More

affordable incinerators

RECYCLABLE WASTE PLASTIC (NON-PVC) 218,693
CARDBOARD 85,046
PAPER 4,956
PVC 15,115
HAZARDOUS WASTE MEDICAL WASTE 1,084
SOLID WASTE CONTAMINATED WITH HYDROCARBONS 300,680
USED ENGINE OIL FILTERS 85,423
HYDROCARBON-CONTAMINATED DIRTS 88,680
COMMON WASTE FIBERS 14,078
USED AIR FILTERS (AUTOMOTIVE AND ALSO SIMILAR) 23,149
INDIVIDUAL PROTECTIVE DEVICES (PPE), INCLUDING INFECTED CLOTHING AND ALSO SIMILAR PARTICLES 130,861
Pig corpses/ roaming pet dogs and also bigger pet carcasses economical incinerators ––.
Lots ability in the variety of up to 300 kg/ Melt rate approx. 50 kg per hour

Temperature Controlled Heater. Burners to be made to meet the Norms of Pollution Control. Modern technology: Heavy-duty covering, to be a top quality, rugged, dependable, affordable Burner with pertinent control, very easy to operate and also self-supporting. Systems to be pre-assembled, pre-piped, pre-wired & & examined prior to Transport/ Export.

Note: Comparable Modern Technology and/ or Tenderers Proposals rate.

Within the structure of an ecological tools & & technology consultation and joint buying, this Procurement/ Notary Bureau welcomes candidates for pre-qualification in the purpose of largely choosing qualified companies to bid for the above tender.
The supply will make up the special devices for efficient waste monitoring as pointed out above for a brand-new personal setting contract management firm with prepared procedures 2013 in Indonesia as well as Thailand, as well as 2015 in West & & East Malaysia to execute those expert services in order to follow the federal governments safety disposal requirements for animal waste in the region as well as to satisfy the higher technical standard in this specific area in order to secure the public and consist of infectious & & contagious infections and also pet triggered conditions. The spread of a brand-new illness of pigs, likewise the ‘‘ Nipah Infection Illness’, first noticeable in 1998 in S.E.Asia, which causes illness and also fatality in both humans as well as pigs, is on the rise once again; as well as the premature death of plants and also boars was recorded in pig farms in Malaysia as well as other locations in S.E. Asia.

Read More

small capacity burners

1    Basic Plant Design    An approved plant must have four distinct sections that demonstrate three principles of Turbulence, Residence Time and Temperature are inbuilt in the plant design .The regulated sections may include but not limited to:

Overall plant layout.
Feed chamber/ charging
Primary Combustion Chamber.
Secondary Combustion Chamber.
Particulate Scrubbers
Acid Gas Scrubbers
The stack/ chimney.
2    Feeding And Charging    Controlled hygienic, mechanical or automatic feeding methods have to be used which will not influence the air temperature in the primary and secondary chambers of the incinerator negatively.

No waste is to be fed into the incinerator:

1.    Until the minimum temperatures have been reached.
2.    If the minimum combustion temperatures are not maintained.
3.    Whenever the previous charge has not been completely combusted in the case of batch feeding.

4.    Until such time as the addition of more waste will not cause the design parameters of the incinerator to be exceeded.

3    Primary Combustion Chamber    The primary combustion chamber must:

1.    Be accepted as the primary combustion zone.
2.    Be equipped with a burner/s burning gas/fuel or low sulphur liquid fuels. Other combustion methods will be judged on merits.

3.    Ensure primary air supply is controlled efficiently
4.    Ensure minimum exit temperature is not less than 850oC

4    Secondary Combustion Chamber (Afterburner).    The secondary combustion chamber must:

1.    Be accepted as secondary combustion zone.
2.    Be fitted with secondary burner/s burning gas or low sulphur liquid fuel or any suitable fuel.

3.    Ensure secondary air supply is controlled efficiently.
4.    Ensure flame contact with all gases is achieved.
5.    Ensure residence time is not less than two (2) seconds.
6.    Ensure the gas temperature as measured against the inside wall in the secondary chamber & not in the flame zone, is not less than 1100oC.

7.    Ensure the oxygen content of the emitted gases is not less than 11%.
8.    Ensure both primary and the combustion temperatures are maintained until all waste has been completely combusted

5    Particulate Removers    A mechanical particulate collector must be incorporated after secondary combustion chamber for removal of particulate pollutants entrained in the flue gas stream. The particulate collectors may include any of the following or a combination thereof:

Cyclone separator
Electrostatic precipitators
Fabric filters
6    Chimney / Stack    1.    The chimney should have a minimum height of 10 meters above ground level and clear the highest point of the building by not less than 3 meters for all roofs. The topography and height of adjacent buildings within 50 meters radius should be taken into account.

2.    If possible the chimney should be visible to the operator from the feeding area.
3.    The addition of dilution air after combustion in order to achieve the requirement of these guidelines is unacceptable.

4.    The minimum exit velocity should be 10 m/s and at least twice the surrounding wind speed (Efflux velocity = wind speed x 2) whichever is higher to ensure no down washing of exiting gases.

5.    Point for the measurement of emissions shall be provided.

7    Instrumentation    Instrument for determining the inside wall temperature and not burner flame temperature must be provided for both primary and secondary chambers.

2.    An audible and visible alarm must be installed to warn the operator when the secondary temperature drops to below the required temperature.

3.    In addition to the above the following instruments may also be required.
A carbon monoxide and/or oxygen meter/recorder
A smoke density meter/recorder
A gas flow meter/recorder
A solid particulate meter/recorder
Any other instrument or measurement that may be considered necessary

8    Location / Siting    1.    Must be sited in accordance with the relevant local municipal authority planning scheme, the topography of the area and be compatible with premises in the neighborhood,

2.    Must be housed in a suitably ventilated room.

9    Emission Limits    1.    Combustion efficiency:

Combustion efficiency (CE) shall be at least 99.00%
The Combustion efficiency is computed as follows;

C.E=             % CO2           x 100
% CO2 + CO

2.    The temperature of the primary chamber shall be 800 ± 50o C

3.    The secondary chamber  gas residence time shall be at least 1 (one) second at 1050 ± 50o C, with 3% Oxygen in the stack gas.

4    Opacity of the smoke must not exceed 20% Viewed from 50 meters with naked eyes
5.    All the emission to the air other than steam or water vapour must be odourless and free from mist, fume and droplets.

6.    The Authority may require that the certificate holder have tests carried out by an accredited institution to determine stack and/or ground level concentrations of the following substances.

Cadmium and compounds as     Cd
Mercury                                      Hg
Thallium                                     Tl

Chromium                                  Cr
Beryllium                                    Be
Arsenic                                       As
Antimony                                    Sb
Barium                                        Ba
Lead                                            Pb
Silver                                          Ag
Cobalt                                         Co
Copper                                        Cu
Manganese                                  Mn
Tin                                               Sn
Vanadium                                     V
Nickel                                           Ni
Hydrochloric                                HCL
Hydrofluoric acid                         HF
Sulphur dioxide                           S02

7.    A 99.99% destruction and removal efficiency (DRE) for each principal organic hazardous constituent (POHC) in the waste feed where:

DRE = [(Win – Wout)/Win]*100
Where: Win = mass feed rate of the POHC in the waste stream fed to incinerator, and
Wout = mass emission rate of POHC in the stack prior to the release to the atmosphere.

8.    The average dioxin and furan concentration in the emissions should not exceed 80ng/m3 total dioxins and furans if measured for a period of 6 to 16 hours.

Note:
All pollutant concentrations must be expressed at Oo C and 1.013 x 10 5 N/m2, dry gas and 11% oxygen correction.

Oxygen correction is computed as:

Es =     21 – Os    x EM
21 – OM

Where:    Es    = Calculated emission concentration at the standard percentage oxygen concentration
EM    = Measured emission concentration
Os    = Standard oxygen concentration
OM    = measured oxygen concentration

10    Operation    1.    Materials destined for incineration should be of known origin and composition and must be only incinerated in a furnace that is registered for the particular type of waste.

2.    A record must be kept of the quantity, type and origin of the waste to be incinerated.
3.    The incinerator must be preheated to working temperature before charging any waste.
4.    The incinerator must not be overcharged.
5.    The incinerator must be in good working order at all times and must not be used if any component fails. Any malfunction should be recorded in a log book and reported to the relevant authority.

6.    The incinerator operator and all relevant staff must be trained to the satisfaction of the relevant control authority.

11    Housekeeping    The site where the incinerator is built must:

1.    Have running water.
2.    Have a solid floor.
3.     Have lighting if 24hrs operation
4.    Have fly ash containerization and storage before disposal.

12    Health & Safety (Protective Gear)    1.    Staff handling waste must be well trained on safe handling of hazardous wastes
2.     Staff must be provided with appropriate  protective gear such as, gas mask, aprons, gumboots, helmets, gloves, goggles.

3.     Caution and Warning signs must be provided.
4.     Fire fighting equipment must be provided
5.     There should be no smoking or eating on the site.

Read More

SHEDDING AND INCINERATION OF SOLID WASTE

Biomedical Waste Any kind of strong or liquid waste which may offer a hazard of infection to people consisting of non-liquid tissue, body parts, blood or blood items and body fluids, research laboratory and also veterinary waste which includes human disease- triggering agents, and discarded sharps (i.e. syringes, needles, scalpel blades).

Base Ash The program non-combustible and also unburned material which remains at the shed site after burning is total. This includes products continuing to be in the burn chamber, exhaust piping as well as air pollution control tools where such tools are used.

Burn Box A huge metal box made use of to shed solid waste. Combustion air is typically provided passively via vents or openings cut above all-time low of package. An exhaust pipe or stack might or may not be affixed.

Industrial Camp A short-lived, seasonal or multi-year facility with a capacity more than 15 individuals and also which has actually been established for study, industrial or commercial purposes. An industrial camp does not consist of a conventional camp or area camp.

Commissioner’s Land Lands that have actually been moved by Order-in-Council to the Federal Government of Nunavut. This includes streets as well as land subject to block land transfers. The majority of Commissioner’s Land is located within municipalities.

Impurity Any type of noise, warmth, resonance or substance and includes such various other substance as the Minister might prescribe that, where released right into the atmosphere,

  • endangers the health, safety or welfare of persons,
  • interferes or is likely to interfere with the normal enjoyment of life or property,
  • endangers the health of animal life, or
  • causes or is likely to cause damage to plant life or to propert

Established Effort The recurring evaluation of chances for decreases and the application of modifications or emission control upgrades that are technically and economically practical as well as which result in on-going reductions in exhausts. Determined initiatives consist of the growth and execution of waste management preparation which is focussed on air pollution avoidance.

De Novo Synthesis The production of complicated molecules from simple molecules.

Setting The elements of the Planet as well as includes

  • air, land and water,
  • all layers of the atmosphere,
  • all organic and inorganic matter and living organisms, and
  • the interacting natural systems that include components referred to in paragraphs (a) to (c) above.

Field Camp A short-lived, seasonal or multi-year center consisting of outdoors tents or other similar short-lived frameworks with a capacity of 15 individuals or less and which has been established for research study, business or industrial objectives. An area camp does not include a conventional camp or industrial camp.

Fly Ash Unburned product that is sent out into the air in the kind of smoke or great particle issue throughout the burning process.

Hazardous Waste A contaminant that is an unsafe great and is no longer wanted or is unusable for its initial designated objective and also is intended for storage space, recycling, therapy or disposal.

Incineration A therapy technology involving the damage of waste by controlled burning at high temperatures.

Incinerator A device or framework planned mainly to incinerate waste for the purpose of lowering its volume, ruining a dangerous material in the waste or ruining an infectious material in the waste. A burner has suggests to regulate the burning and air flow processes.

Assessor An individual assigned under subsection 3( 2) of the Environmental Protection Act and also consists of the Principal Environmental management Officer.

Changed Burn Barrel A metal drum made use of to burn waste that has been fastened with gadgets or features which supply limited boosted warm generation, heat retention as well as holding time.

Open Burning of waste with restricted or no control of the melt procedure. For clarity, open burning includes burning on the open ground or utilizing a melt box or unmodified or changed burn barrel.

Certified Individual An individual who has an appropriate level of expertise and experience in all pertinent aspects of waste management.

Accountable Party The owner or person in charge, administration or control of the waste.

Smoke The gases, particle matter as well as all other products of combustion produced right into the environment when a substance or product is melted consisting of dust, triggers, ash, soot, cinders and fumes.

Solid Waste Unwanted solid materials discarded from a house (i.e. single or numerous property residences, other similar irreversible or temporary residences), institutional (i.e. institutions, government centers, healthcare facilities as well as health and wellness centres), business (i.e. stores, dining establishments) or industrial (i.e. mineral, oil as well as gas expedition and growth) center. For quality, strong waste does not consist of biomedical waste, hazardous waste or sewage sludge.

Typical Camp A short-lived or seasonal camp used mostly for camping, searching, angling or other typical or social tasks. A typical camp does not include a field camp or industrial camp.

Unmodified Burn Barrel A steel drum made use of to burn waste that has not been affixed with tools or functions which provide for enhanced warm generation, warmth retention as well as holding time.

Unattended Wood Timber that has actually not been chemically fertilized, painted or likewise changed to boost resistance to insects or weathering.

Waste Audit An inventory or research of the quantity as well as type of waste that is generated at a location.

Read More