Tag: waste incinerator

Pyrolytic Double Chamber Incinerator Small Size:Burning Rate:30-45 kg/hr;Maximum Load Capacity:400 kg

Items/Model

TS50(PLC)

Picture

Principle

Solid Waste Incineration

Burn Rate

30-45 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

560L

Internal Dimensions

100x80x70cm

Secondary Chamber

280L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Oil Consumption (kg/hour)

Average 13.3

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

800L

Feed Door

70x55cm

Chimney

5Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800–-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

4500kg

External Dimensions

230x130x155cm

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21

Read More

Medium Size:Burning Rate:60-80 kg/hr Pyrolytic Double Chamber Incinerator

Items/Model

TS100(PLC)

Picture

Principle

Waste Incineration Treatment

Burn Rate

60-80 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

1200L

Internal Dimensions

120x100x100cm

Secondary Chamber

600L

Smoke Filter Chamber

Yes(Dry Scrubber)

Feed Mode

Manual

Voltage

220V

Oil Consumption (kg/hour)

Average 20.4

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

1100L

Feed Door

80x60cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800–-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

6000kg

External Dimensions

260x150x180cm


The requirement is for a pyrolytic double-chamber incinerator. The incinerator shall be capable of using diesel 
fuel as a supplemental fuel oil.
It should incorporate an Air Pollution Control (APC) System suitable for basic emission control.
The proposed incinerators shall be appropriate for critical harsh environmental conditions, suitable for rapid 
deployment, and different climate zones (e.g. desert, tropical country, mountain, etc.) in which there are several 
variations of the relative natural forces (e.g. temperature, humidity, wind, etc.) for a minimum period of 10 years 
if the specified maintenance schedule is followed.
The incinerators should be supplied assembled, whenever possible, and all parts and components should be 
packaged on pallets in order to be transported via road, air (via helicopters or air-cargoes, e.g. MI8 or C130) 
and via sea in a 20’ ISO sea shipping containers.
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21

Read More

Large Size Burning Rate:150-200 kg/hr Solid Waste Equipment Primary and Secondary Combustion Chamber Incinerator

Items/Model

TS500(PLC)

Picture

Principle

Waste Incineration Treatment

Burn Rate

150-200 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

2700L

Internal Dimensions

190x120x120cm

Secondary Chamber

1300L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Oil Consumption (kg/hour)

Average 28

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

1400L

Feed Door

90x80cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800–-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

15000kg

External Dimensions

400x210x300cm(without chimney)

The air supply should be controlled efficiently;
Flame contact with all the gases should be achieved;
The minimum combustion temperature of the primary chamber should not be less than 850°C;
The primary combustion chamber should be equipped with a means to provide supplemental liquid fuel supply.
The primary chamber should be cold face refractory lining, with a minimum thickness 100 mm.
The following conditions should be met in the secondary combustion chamber:
The air supply should be controlled efficiently;
Flame contact with all the gases should be achieved;
The size of the secondary chamber should be properly designed to ensure that the gas retention time should not be less than 2 seconds;
The secondary chamber should be cold face refractory lining, with a minimum thickness 100 mm;
The chamber should incorporate an integrated combustion burner air fans with automatically controlled distribution;
The gas temperature, as measured against the inside wall in the secondary chamber (not in the flame zone) should not be less than 1,100°C;
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21

Read More

hiclover incinerator 100-150kgs per hour

Model

YD-100

Picture

Burning Rate

100-150 kgs/hour

Primary Combustion Chamber

2000 Liters

Secondary Combustion Chamber

500 Liters

Feed Mode

Manual

Voltage

220V/380V

Power

2.5Kw

Fuel Type

Diesel Oil

Burner

Italy Original

Oil Consumption (Diesel Oil)

Average 28 kg/hour

Gas Consumption (Natural Gas)

***

Internal Dimensions

180x115x98 cm (primary chamber)

External Dimensions

270x185x280cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

200 Liters

Door Opening

55 x 80cm

Chimney Length

6.0 Meters

Chimney Type

Steel

Equipment Gross Weight

9000 kgs

Operation Technical Specifications

Primary Chamber Temperature

800–-1000

Secondary Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Burning Efficiency

98%

Waste Lower Calorific Power

3500Kcal


HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-22

Read More

Large General waste incinerator Burn Rate up to 250kg per hour

Items/Model

TS300(PLC)

Principle

Waste Incineration Treatment

Burn Rate

Average 250 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

2000L

Internal Dimensions

170x120x100cm

Secondary Chamber

1000L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

2.5Kw

Oil Consumption (kg/hour)

Average 28(DO)

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

1000L

Feed Door

80x60cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800–-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

11000kg

External Dimensions

400x210x300cm(without chimney)

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-22

Read More

Medical Waste Incinerator for Coronavirus Disease

Coronavirus Disease 2019 (COVID-19) pandemic continues all over the world, clinics,hospitals,goverment may need to consider on-site disposal for the infectious 

medical waste. The medical waste incinerators that has been effectively used to dispose of hazardous waste during 

viral outbreaks like Ebola. HICLOVER.COM reaches temperatures of up to 1200oC and is able to destroy health care waste 

for laboratories, small clinics, and hospitals treating patients of the Novel Coronavirus (COVID-19) such as linens, sharps, gauze, gowns, etc.

Clicky




Open chat








Read More

waste disposal incinerator

Incinerator but the size of chamber > 2000 x >1200 mm. Prepare for burn LIQUID Waste +/- 20 liter/hr.
Fueled by Heavy OIL Burner.waste disposal incinerator, capable of handling both wet and dry garbage.. Which include house hold wastes and dry leaves.
The chamber of the incinerator should be able to hold about 200 – 250 kilogram of waste at a given time. edical Waste Incinerators.
The mobile unit is our priority then the fixed units. Medical Waste Incinerators. The mobile unit is our priority then the fixed units.
a;  Batch Capacity for each model, how much load can we put in one time. I need tio under stand in term of batch load one time I can ut in Kgs.
b:  Burning capacity per hour, to know how much time it will take to burn one batch and what is cooling timem for each one.
c: How many batch can we put in each day basis per 24 hours.
d: Most of systems will be run on Gas, so I need to know the required pressure of gas in psi to run the system without any problem.
e; I do wish to know an average life of system and after how many years we need the repair of linning etc.

2. What is your minimum capacity and maximum capacity incinerator.

3. You do provide secodn hand incinerator in good working condition.
4. We need only double chamber double burner incinerator.
5. Please send us DEFRA and DADR approval reports by attachment, copy of ISO and summary of gas emmission report from incinerators.

Read More

Refractory Concrete Incinerator

2 medical waste incinerators model YD-50, 150 kg feed capacity, 220/380 V, 50 Hz c/w 5 mtr. chimney.
Bio-medical waste management plant requirements:

Disinfecting/sterilizing the contaminated medical wastes, main combustion chamber, post combustion chamber, heat exchanger, ash removal units and flue gas treatment systems, with the following details:

Hourly capacity of the system:           from 250 up to 500 Kgs/ hour

Duration of operation:                        from 14 up to 18 hrs/ day

Fuel type to be used:                         Diesel or alternative

Calorific value of the waste:               3500 up to the maximum limit kcal/ Kg

Minimum operating temperature of primary chamber: 1000 degrees celcius

a smaller  capacity of 150 to 250  kg/feed capacity
will be good for comparison. Our main byproducts are the slaughtered unwanted carcass.

•             Using diesel as fuel

•             Capacity 50kg per hour

•             chambers material: Refractory Concrete

•             Number of chambers: Two

•             Manual feed
solicito un horno crematorio para mascotas, de una capacidad de 80 kl, aprox. solo una unidad, especificaciones tecnicas, totalmente industrial, atte. erika martinez peru

Read More

Containerized Mobile Incinerator Medical Waste Incinerator Model CA50

HICLOVER – Containerized Mobile Incinerator Medical Waste Incinerator Model CA50


Model

CA50

Picture

Waste Treatment

Medical Waste Incineration Treatment

Feed Capacity

Average 100 kgs per feeding

Burning Rate

Average 50 kgs per hour

Burning Time per Feed

Average 2 hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Voltage

220V

Power

1.0 Kw

Fuel

Diesel oil

Burner

Italy Burner

Feed Mode

Manual

Temperature Monitor

Digital Display

Fuel consumption (Oil)

Average 16.9 Kgs/Hour

Internal Dimensions

100x80x70cm (Primary Chamber)

External Dimensions

230 x 130 x 155cm (main body)

Waste combustion chamber

560Liters

Post Combustion Chamber

280Liters

Oil Tank Capacity

200 Liters

Door Opening

70 x 50cm

Chimney

5.0M

Gross Weight

4500kgs

Chamber Material

Firebrick ,Refractory Concrete

Max. Heat Value

166,000Kcal/Hr.

Operation Technical Specifications

Solid Chamber temperature

8000C -10000C

Gas Chamber temperature

10000C -12000C

Chamber Anti-Rate

17500C

Residency time

2.0 Sec.

Burning efficiency

98%

Waste Lower Calorific Power

3000Kcal


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-24

Read More

Small Medical Waste Incineraotr for COVID-19 Bio Hazardous Medical Waste

HICLOVER – Medical Environmental 

Model

YD-20

Picture

Burning Rate

Average 20 kgs/hour

Feed Capacity

Average 60 kgs/feeding

Primary Combustion Chamber

360 Liters

Secondary Combustion Chamber

200 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

1.0 Kw

Fuel Type

Diesel Oil/ Natural Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

Average 13.3 kg/hour

Gas Consumption (Natural Gas)

***

Internal Dimensions

100 x 60 x 60cm (primary chamber)

External Dimensions

145 x 90 x 260cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

200 Liters

Door Opening

48 x 60cm

Chimney Length

5.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

2300 kgs

Operation Technical Specifications

Primary Chamber Temperature

800–-1000

Secondary Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Burning Efficiency

98%

Waste Lower Calorific Power

3000Kcal

Wearing a face mask to keep out the coronavirus has become an essential part of everyday life for many people 
around the world, but the huge amount of waste being created as the single-use items are tossed aside has the 
potential to become an ecological disaster.

How to deal with discarded face masks, which number in their millions or even billions, is another headache for 
Chinese authorities already caught between containing the viral disease and limiting the economic damage caused by it.

The country’s inadequate medical waste treatment capabilities have also been put under the spotlight, environmental experts said.

Environment and health authorities say masks and other protective gear, especially items used by medical personnel and 
people infected with the coronavirus, should be treated as clinical waste, and sterilised before being incinerated at high 
temperatures at dedicated facilities.

While it is difficult to get an exact figure on the number of discarded masks, it is reported that the volume of medical 
waste in Wuhan, the city in which the epidemic began in December, had quadrupled to more than 200 tonnes a day last 
week, according to mainland Chinese media reports.

The total amount of medical waste gathered across Hubei province on February 24 totalled 365 tonnes, of which 60 per 
cent came from hospitals, the report said.

By comparison, Wuhan produced 17,000 tonnes of medical waste in the whole of 2018, according to the country’s top 
environment watchdog.

Eric Liu, a toxic waste specialist at Greenpeace’s Beijing office, said China had a huge shortage of waste disposal facilities, 
specifically those capable of handling clinical waste.

“The waste treatment capacity in China, especially in terms of medical and hazardous waste, is barely enough to cope 
with everyday needs, let alone the country’s biggest public health crisis in decades,” he said.

While the environment ministry said most medical waste was being properly dealt with in major cities, just 31 per cent 
of the country’s 629,000 tonnes of medical waste were treated in 2015, up from 24 per cent in 2008, Xinhua reported 
last year, citing an industry study.

Du Huanzheng, director of the Recycling Economy Institute at Tongji University in Shanghai, also expressed concerns 
over the widening supply-demand gap in medical waste treatment, but said a large number of new facilities were being built or planned.

“The disposal of medical waste is a major part of the battle against the outbreak, which is a wake-up call for the government 
to speed up the construction of new facilities and research into waste treatment technologies,” he said.

The coronavirus outbreak could be the catalyst for expanding the medical waste sector and lead to the building 
of more incineration facilities, the experts said.

They said combustion remained the preferred means for disposing of medical waste in China, although industrialised 
countries were phasing out incinerators due to health and environmental concerns.

Masks could be split into three categories, Liu said. While clinical waste must be disposed of at dedicated incineration
 facilities, masks used by healthy people could be tackled in a similar way as household waste, which was burnt in industrial furnaces, he said.

The real challenge came from those used by people who were placed under home quarantine or others with mild symptoms, he said.

“There is a grey area over this kind of used mask, which are not under the jurisdiction of medical institutions but should 
be treated in accordance with standards for medical waste.”

In Wuhan, authorities are scrambling to find solutions to the challenge. The environment ministry said the city’s five incinerators 
for household waste disposal and various industrial furnaces at cement and other factories had also been assigned to help clear 
the garbage backlog, which stood at about 190 tonnes as of February 24.

According to a report by China Economic Daily, Wuhan is rushing to build more medical waste treatment plants near hospitals, 
including ones near Huoshenshan, Leishenshan and Jinyintan hospitals that will treat nine, 15 and four tonnes of clinical garbage respectively on a daily basis.

A total of 17 temporary storage facilities for medical waste, with a combined capacity of more than 1,000 tonnes, have also been built.

While authorities had to transfer some of the garbage produced in Wuhan to neighbouring cities for incineration, they have also 
tried to enlist help from waste treatment companies around the country.

China Shipping Group and a company in Anhui deployed a number of mobile medical waste incineration cabins to Wuhan last month, Xinhua reported.

The incinerators, each of which is capable of processing five tonnes of waste a day, were first used in 2003 during the Sars outbreak.


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-24

Read More