Medical Waste Incinerators|Auto Roll Air Filters

Complete combustion converts waste into inert bottom ash with minimal creation of smoke, fly ash and hazardous gases. Several factors influence this process including the heating value, wetness and chemical composition of the waste itself, operating conditions in the burn chamber (i.e. temperature, holding time and turbulence) and operator skill. The method used is important […]

* Burner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve. * A secondary injection of air to ensure perfect oxygen content. 19.    A control box ensuring the complete cycle of combustion. 20.    Fan: * Electro-ventilator distributing the secondary […]

* medical incinerators, The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and insulates bricks in order to assure a minimum temperature on the outside sheet metal. * Composition of the refractory; ?    Refractory concrete : ?    . Thickness    : ≥100 mm ?    . Nature: 42% […]

1.    Capacity of destruction in weight: 60 Kg/h. 2.    It should be able to operate not less than 10 hours/day 3.    This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc… 4.    Design Specification : Types A, B, C, D, and E of medical waste 5.    “PYROLYTIC” […]

INCINERATEUR DE DECHETS HOSPITALIER hospital incinerator design SPECIFICATIONS TECHNIQUES. Capacité destructive de 55 Kg/h jour de déchets hospitaliers  avec un p?.c. i jusqu’à 3.200 Kcal/Kg 1)Type de déchet hospitalier 2)Pouvoir calorifique inférieur                                                                        3.200 kcal/kg 3)Humidité                                                                                                          20% 4)Teneur  en cendres et/ou inertes                                                                       8% 5)Capacité destructive nominale                                                                         55 kg/h 6)Volume chambre de combustion                                                                     1,65 m3 7)Volume chambre […]

Our normal activities generates 2-5 tons of assorted waste materials per day which range from condemned carcasses, and medical incinerator primary combustion price other wastes all which need to be incinerated at above 800Centigrade measured flue exhaust gas.To be used by small hospitals and clinics to safely dispose of infectious and pathological wastes. Load Capacity […]

Capacity    Not less than 500Kg/hr. Operation    24hr-7days/week continuous operation. Combustion chamber    2 combustion chamber. Temp.    First combustion chamber 800-1000 C. Secandry combustion chamber 1000-1200 C, with the possibility to be upgraded to 1400 C. Combustion Efficiency    99.99% Retention time    Of the flow gases not less than 2 Sec in the hot portion. Excess Oxygen concentration   […]

1    Basic Plant Design    An approved plant must have four distinct sections that demonstrate three principles of Turbulence, Residence Time and Temperature are inbuilt in the plant design .The regulated sections may include but not limited to: Overall plant layout. Feed chamber/ charging Primary Combustion Chamber. Secondary Combustion Chamber. Particulate Scrubbers Acid Gas Scrubbers The […]

the following containerized incinerators. (Kitchen and accommodation and grey water and black water plant removing waste) we need incinerator is each function separate are all in one incinerator we need informed. Plant we installing for our accommodation barge used in an offshore marine construction project. 200 People would be accommodated onboard. WASTE INCINERATORS RECOMMENDATIONS china […]

waste incinerator manufacturer china, Waste chamber Chamber capacity 300 kg Chamber volume .54m3 Chamber size (outside) Width: 91cm, Height: 86cm Length: 152cm Door opening 66 x 76 cm Height to door 84 cm Height to top of stack 5.4 m Suggested slab size (L x W x Thickness) 1.8 m x 2.4 m x 10 […]

NJCTW.COM