ADVANCED MEDICALWASTE BURNER

Incinerator model A.
Burn Rate 65kg/h minimum.
Weight (kg), please suggest:.
Secondary Chamber.
Gas Retention Time – – 2 Seconds. Fuel – Diesel/LPG/LNG, please suggest. Power Supply for – Control Box – 220V-240V 50Hz single phase. Minimum operating temperature level 850 ° C, please suggest. One year Spare Components Package for complete maintainability. 10m Pipe Pipeline, indicate size.
I000 Litre Gas Container + Pipe System, show quantity.
Added chimney extension, suggest height.
Guarantee, indicate no of years.
i. The main combustion chamber will be accepted as the main burning zone;.
ii. The minimum combustion temperature level of the primary chamber will not be less than 800 degrees C;

Secondary combustion.
The home time in the second chamber shall not be less than 2 seconds;.
The gas temperature level as measured versus the within wall surface in the second chamber, not in the fire area, shall not be much less than as shown in Lots 1-7;.
Both the main as well as the second temperature levels will be kept till all the waste has been completely combusted;

Smokeshaft.
The smokeshaft shall have a minimal height of 4 meters over ground degree;.
The minimum exit speed of the emissions shall not be less than 10 metres/second;

Temperature Level Warnings.
A distinct and/or visible alarm system to advise the driver when the secondary temperature drops to listed below the required temperature;

General.
Control box can be removed as well as mounted on separate stand at the very least 1.5 meters from incinerator at around 1.6 meter elevation;

Great Deal 2.
Thing 5 Incinerator design B.
Burn Rate 150kg/h minimum.
Weight (kg), please indicate:.
Additional Chamber.
Gas Retention Time – – 2 Seconds. Diesel/LPG/LNG, please indicate. Power Supply for Control Box- 220V-240V 50Hz solitary stage.
Minimum running temperature 920 ° C, please suggest.
One year Spare Parts Package for full maintainability.
Thing 6 10m Hose pipe Pipe, indicate size.
Item 7 I000 Litre Gas Storage Tank + Pipe System, suggest quantity.
Product 8 Added chimney extension, indicate elevation.
Guarantee, show no of years.
Great deal 3.
Thing 9 Incinerator design C.
Burn Rate 250kg/h minimum.
Weight (kg) please indicate:.
Second Chamber.
Gas Retention Time 2 Secs.
Gas Diesel/LPG/LNG, please indicate.
Power Supply for Control Box 220V-240V 50Hz single phase.
Minimum operating temperature level 920 ° C, please indicate.
One year Spare Components Bundle for complete maintainability.
Item 10 10m Hose pipe Pipe, indicate length.
Thing 11 I000 Litre Gas Container + Pipe System, indicate volume.
Item 12 Additional chimney extension, show height.
Warranty, indicate no of years.
Great deal 4– Heat Waste Burner.
Thing 13 HTW Burner design D.
Burn Rate – – 150kg/hour minimum.
Weight (kg), please show:.
Secondary Chamber.
Gas Retention Time 2 Secs.
Fuel Diesel/LPG/LNG, please suggest.
Power Supply for Control Box 220V-240V, single stage 50-60Hz.
Minimum running temperature 1200 ° C, please indicate.
One year Spare Components Bundle for total maintainability.
Item 14 10m Hose pipe Pipe, suggest length.
Item 15 1000 Litre Fuel Tank + Pipe System, show quantity.
Product 16 Additional smokeshaft expansion, show height.
Service warranty, show no of years.
Great deal 5– Mobile Incinerator.
2. Incinerator gives 2 chamber incineration as well as holds gasses for a minimum of 2 seconds.
3. Each incinerator has to have adequate labelling for parts/areas of high work health and safety danger on the incinerator.
4. Evidence their item satisfies pertinent nationwide or international discharges requirements, such as the USA Epa, UK Department for Setting Food.
& & Rural Matters, or European Union regulations and regulations.

Item 17 Mobile Incinerator model E.
Burn Rate 50kg/h minimum.
Weight (kg), please show:.
Secondary Chamber.
Gas Retention Time – – 2 Seconds. Gas – Diesel/LPG/LNG, please show. Power Supply for – Control Box – 220V-240V 50Hz single phase. Minimum operating temperature level 850 ° C, please show. One year Spare Components Package for total maintainability. Product 18 10m Hose Pipeline, show size.
Item 19 1000 Litre Gas Storage Tank + Pipe System, show volume.
Product 20 Additional chimney expansion, indicate height.
Whole lot 6– Mobile Burner.
Product 21 Mobile Incinerator design F.
Burn Rate 100kg/h minimum.
Weight (kg), please indicate:.
Secondary Chamber.
Gas Retention Time – – 2 Seconds. Fuel – Diesel/LPG/LNG, please indicate. Power Supply for – Control Box – 220V-240V 50Hz single phase. Minimum running temperature 850 ° C, please suggest. One year Spare Parts Plan for full maintainability.
Product 22 10m Hose Pipe, show length.
Thing 23 1000 Litre Fuel Storage Tank + Pipeline System, suggest quantity.
HTW Mobile Incinerator design G.
Burn Price 100kg/h minimum.
Weight (kg), please indicate:.
Additional Chamber.
Gas Retention Time – – 2 Seconds. Fuel – Diesel/LPG/LNG, please indicate.
Power Supply for Control Box – – 220V-240V 50Hz solitary stage.
Minimum running temperature 1200 ° C, please suggest.
One year Spare Components Bundle for total maintainability.
10m Pipe Pipe, indicate size.
1000 Litre Fuel Storage Tank + Pipeline System, suggest volume