Author: admin

animal burner

The incinerator plant shall include a control board for its treatment. On the control panel we will have an aesthetic display of the chamber temperature level levels. This aesthetic screen needs to maintain an eye and handle on the burner in addition to his performance. Capacity of destruction in weight will be 60 Kg/h. It

Read More
small capacity incinerators

1    Basic Plant Design    An approved plant must have four distinct sections that demonstrate three principles of Turbulence, Residence Time and Temperature are inbuilt in the plant design .The regulated sections may include but not limited to: Overall plant layout. Feed chamber/ charging Primary Combustion Chamber. Secondary Combustion Chamber. Particulate Scrubbers Acid Gas Scrubbers The

Read More
china animal cremation

The panel shall comprise of a compartment for the connection of power and control cables. Passage for power cables and control cables shall be made by the bottom part of the switchboard.         The drawer shall be locked in the isolated position by padlocks.   1.Two systems are required to be installed

Read More
china incinerator

Stack size shall be in accordance with the manufacturer’s recommendations. Stacks shall be the forced-air type and   completely self-supporting and unattached to nearby structures. As a minimum, stack heights shall minimize   downwash of stack emissions due to aerodynamic influences from nearby structures and be calculated in accordance   with DoD 4715.05-G, Overseas Environmental

Read More
china medical incinerator

the following containerized incinerators. (Kitchen and accommodation and grey water and black water plant removing waste) we need incinerator is each function separate are all in one incinerator we need informed. Plant we installing for our accommodation barge used in an offshore marine construction project. 200 People would be accommodated onboard. WASTE INCINERATORS RECOMMENDATIONS china

Read More
mobile burner

Petrol: diesel Consumption: 8-10liter/hour Capacity: to cremate (carrion and spoils) 350-400kg/hour Temperature: 900-1350?C Operation temperature: -30~40?C Incinerator weight: 1800-2000 kg Volume: 0.70-0.80m/cube Exterior dimension: 1.4-1.6*1.0-1.15m (L*W) A heater stands for a complete service to the problem of disposal of all clinical facility waste kinds. The fluid fuel is diesel. The burner ought to meet the

Read More
Wastes That Can be Melted or Blazed

waste itself, running problems in the shed chamber (i.e. temperature degree, holding time as well as likewise disturbance) and also motorist capability. Waste having chlorinated materials (i.e. chlorinated solvents and plastics, PVC piping, lumber treated with pentachlorophenol or PCB-amended paint, aquatic driftwood) should be divided from different other waste as their burning will absolutely result

Read More
incinerator china

oElectro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of the automatic cycle. Controls and regulations: Control box watertight to dust, including:   A switch circuit breaker for each engine (ventilators and burners). A timer with adjustable temporization for the regulation of each burner.

Read More
healthcare facility incinerator

* Burner with gas, mono-bloc spreading helping kind with straight fire, lights as well as safety and safety of digital ignition, long-term ventilation, electro-magnetic sluice gate of plan and dividing shutoff. * An additional shot of air to ensure excellent oxygen material. 19. A control box guaranteeing the overall cycle of burning. 20. Fan: *

Read More
medical incinerators

* scientific burners, The insulation of the burning chamber require to be made up of refractory bricks, having a. high web content of aluminium and likewise protects bricks in order to make sure a minimum temperature level on. the outdoors sheet metal. * Structure of the refractory; ? Refractory concrete:. ?. Density: ≥ 100 mm.

Read More
Biological Waste Incinerators