Author: admin

pet incinerator price

j) Controls i) The controls (i.e., switches, knobs, etc.) should be visible and clearly identified, and their functions should be self-evident. ii) Device design should prevent misinterpretation of displays and control settings. iii) Switches and controls should be protected against accidental setting changes (e.g., due to someone brushing against the panel). iv) Controls should be

Read More
Relating To Hiclover Medical Enviromental

HICLOVER, Nanjing Clover Medical Development Co., Ltd, supply system options for medical ecological management, animal as well as also household pet dog cremation design, various other municipal solid waste incineration job. We offer single combustion chamber, double burning chambers, 3 burning chambers as well as likewise multi-combustion chambers waste incinerators for research laboratory, center, university

Read More
Required Specs for Mobile Burner

Functional Abilities PROCESS MINIMUM 1 TON PER DAY OPERATED WITH LIMITED TRAINING REGULAR MAINTENANCE CAN BE COMPLETED WITH LIMITED TRAINING COMPLIES WITH EURO / OR US-EPA EMISSION STANDARDS ABILITY TO BURN WASTE LUBRICANTS (POL) HANDLE ORGANIC SOLIDS (TO INCLUDE RMW) DEPLOYABLE MOBILE 24 HRS OF CONTINUOUS USE AUTOMATIC LOADING SYSTEM AUTOMATED ASH REMOVAL SYSTEM GAS

Read More
waste incinerator manufacturers from china

Incinerate: medical waste and general waste Capacity to burn waste: 400-500kg/hr Fuel: Diesel Fuel Consumption: 10 liters/hr maximum Incineration temperature: 950-1300 degrees centigrade Casing: thick (min 5mm) stainless steel casing and fully insulated to withstand sea humidity Voltage 220/240v or 380/415V Frequency 50Hz high-capacity, powerful, European Standard incinerator,ideal for high volume incineration,with integral after-burner for

Read More
clinical facility incinerator manufacturers

SCHEDULE 2 TECHNICAL SPECIFICATIONS OF THE INCINERATOR General Description Previous experience in the supply, installment as well as appointing of burners Overall plant layout Feed chamber/charging Primary combustion chamber Particulate scrubbers Acid gas The stack/chimney. Minimum capacity of primary chamber = 10cubic meters Burn rate (rate of waste incineration) = 10 kg per hour Should

Read More
mobile incinerator china

Temperature:  ambient temperature ranges between 21 – 450  C or more in poorly ventilated rooms. The hottest month of the year is March. Environmental temperature can be such that inferior rubber and plastic materials can easily melt or deformed. Bidders must ensure all materials will be able to withstand such temperatures   4)  Humidity: humidity

Read More
health center incinerator provider

As Much As 600kgs per ten-hour day of Kind IV pathological waste or red bag waste ranked at 2200 BTU’s per kg, based upon batch packaging two times daily. Burner, 20 kg/hr Burn Capability (min. 1200 kgs. Waste Feed Ability daily) (4-6 humans resources treatments) (Power Supply 380V, 50Hz, 3Ph). Capability: 30 kg/hr. Number item:

Read More
lab incinerator china producer

Incinerator double chamber with capacity 1.5 m3/batch or 6 m3/ day, digital thermocontrol array 0‐1200 C, thermocouple, air supply capacity 10m3/ min, power use 1.2 kWH/ hr, power 3 stage with netral, cooling water sprinkler ability 5L/ minute, finished with refractory (insulation, castable, ceramic covering) and also PLC SUPPLY, INSTALLMENT In Addition To COMMISSIONING OF

Read More
burner kind of pyrolytic clinical waste burner capacity

Including:Incinerator: Structure to be specified The mark to be specified Water temperature: 800 to 1000 ° C; Refractory Temperature of more than 1100 ° C + obtained; Capacity: 20-50 kg / hour Fireplace: 4 to 6 meters high; Dimension 70 cmx70 crn Height: 1.10 meters Fuel: coal; Aspiration: natural – A receiving cage for biomedical

Read More
diesel oil fired medical waste incenerator

Heat Waste Incinerator Layout D. MEGABYTES 750XL Melt Rate-150Kg/ hr minimum Weight( Kg) -4000 kg Added Chamber (double chamber with post-burning) Gas Retention Time 2 2nd Gas Diesel Power Supply for control box 220V-240, solitary phase 50-60Hz Minimum operating temperature degree 1200 oC One year extra parts bundle for full maintainability 10m pipe pipe. 1100

Read More
Biological Waste Incinerators