50 to 60kg/hr as well as 100 to 120kg/hr diesel powered incinerator

50 to 60kg/hr and 100 to 120kg/hr diesel powered heater.1. Capability to Blaze the Adhering To Types of Waste: Family members waste, glass, steel, lightweight light weight aluminum containers as well as additionally window extrudes, steel containers (shattered), wood, tires, soft goods, plastic containers, stress packs, medical waste along with quarantine waste. 2. Required Blazing

Read More
For incineration, fundamental and likewise pathological burners

Main unit Application    For incineration, general and pathological Capacity      50 – 60 kg/h burn rate Type    Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit Operating time                   Minimum 8 hours daily Operating temperature        From 850 0C to 1200 0C, Automatic controlled Residual Ash                 

Read More
2 combustion chambers type heater

Load Capacity minimum:  1500 kg Burner fuel type:  Diesel Burner fuel rate max.:   20-25 Liter diesel/ per hour Burners minimum: 3 Burning rate minimum: 200-300kg/per hour Furnace bar area minimum: 2 м3 Fuel tank capacity minimum: 300L Main chamber burning temperature min. 1100 0C Afterburner chamber burning temperature min.  1300 0C Power supply 220V Incinerator

Read More
Gasified incineration for melting medical wastes burner

Gasified incineration for shedding medical wastes. Gas kind: Gas Developed to melt disposables that can as well as should certainly be destroyed on-site. Theses wastes include also contaminated and infectious “red bag.” Surgical dressings, plastic assessment tools as well as different other wastes. Quick, total, efficient garbage disposal. Twin chamber combustion, Chambers insulated and also

Read More
Containerized diesel fueled burners

Heater Kind: Containerized, gasoline Burning Price:100–– – – 120kg/hour. Minimum Operating Temperature:850 o C( key combustion). Optimum Operating Temperature:1450 oC( Afterburner chamber). Extra Burning Ability: Compulsory. Density Insulation:20 mm High. Refractory Dispersing: Minimum 65mm. Strong refracting lining to hold up against:1500 oC. Common stress out time: optimum:3 personnels. Fuel kind: Diesel. Gas Intake in L/hr:7.5

Read More
Diesel/LPG/LNG burning vital burning chamber/primary combustion burner

Key burning Diesel/LPG/LNG burning vital burning chamber/primary burning area Second burning Residence time in the second chamber not less than 2 secs Both essential along with the second temperature levels maintained up until all the waste has in fact been entirely stired up Chimney Chimney with a very little height of 4 meters over ground

Read More
Needs for Twin Chamber Heater

BURNER DESCRIPTION The Version is for as much as 300kgs capability per batch bunches in addition to will absolutely lose at around 55kgs per hour. The system has leading packing style and has a strong refractory concrete lining for optimal heat retention. Gadget have huge leading cover for extremely easy loading, along with especially made

Read More
PROGRESSED MEDICALWASTE HEATER

Incinerator design A. Burn Rate 65kg/h minimum. Weight (kg), please recommend:. Second Chamber. Gas Retention Time – – – – 2 Secs. Power Supply – for – Control Box – 220V-240V 50Hz solitary stage. 10m Pipe Pipeline, show size. I000 Litre Gas Container+ Pipeline System, show quantity. Included chimney expansion, suggest elevation. Guarantee, indicate no

Read More
a burner for food waste as well as also polythene waste administration

an incinerator for food waste and polythene waste administration. based on our needs we would such as the YD 15C tiny incinerator.Mixed Biomedical waste Incinerator.Contract period: To be chosen by the provider Negotiation terms:100% prepayment via banks TT after signing of contract. Please validate your resolution to perform this contract job by sending handout and

Read More
3 Combustion Chambers MEDICAL WASTE BURNER

Model WS-35 Image Burning Rate Ordinary 35 kgs/hour Feed Ability Average 80 kgs Main Burning Chamber 460 Litres Secondary Burning Chamber 200 Liters 3rd Burning Chamber 200 Litres Smoke Filter Chamber Damp Scrubber System Feed Setting Handbook Voltage 220V Power 2Kw Fuel Type All-natural Gas/LPG Burner Italy Original Oil Intake (Diesel Oil) *** Gas Consumption

Read More