Advanced Medical Waste Incineration Systems for Hospitals and Diagnostic Laboratories

Advanced Medical Waste Incineration Systems for Hospitals and Diagnostic Laboratories


Healthcare facilities―including hospitals, clinics, and medical testing centers―generate sensitive waste streams that demand secure and complete destruction. Items such as plastic syringes, disposable protective gear, and laboratory residues pose infection and environmental risks if improperly handled. The HICLOVER dual-chamber incinerator offers a reliable and regulatory-compliant solution for medical waste disposal, combining high-temperature combustion with PLC automatic control for precision and safety.


The Growing Need for Reliable Medical Waste Treatment

As healthcare infrastructure expands across Africa, the Middle East, and Southeast Asia, hospitals and clinics face increasing pressure to comply with modern waste management standards. Regions like Tanzania, Indonesia, and Jordan have seen new testing centers and mobile clinics producing large volumes of infectious waste, often without centralized treatment facilities.

In such contexts, the on-site medical waste incinerator becomes critical. It ensures the complete thermal destruction of sharps, plastics, and contaminated materials while preventing open burning or unsafe disposal practices.


HICLOVER Dual-Chamber Design

The HICLOVER medical incinerator series integrates robust engineering and automation to ensure both operator safety and emission compliance. Each system features:

  • Primary combustion chamber (850C950 °C) for waste destruction.

  • Secondary combustion chamber (≥1100 °C, ≥2 s retention time) for gas purification.

  • PLC automatic control for real-time temperature monitoring and operational safety.

  • High-alumina refractory lining for durability and heat retention.

  • Diesel, LPG, or natural gas burners with adjustable output for energy efficiency.

  • Optional flue-gas filtration units (dry scrubber, quench tower, or bag filter).

These systems ensure complete oxidation, minimize odor and smoke, and maintain stable operation even during continuous hospital waste feeding.


Application in Healthcare and Laboratory Environments

The incinerators are ideal for:

  • Urban and regional hospitals handling mixed medical waste.

  • Rural health centers requiring autonomous, easy-to-maintain solutions.

  • Diagnostic and testing laboratories producing biological samples and contaminated materials.

In Kenya, Cambodia, and Iraq, for example, decentralized incineration systems allow facilities to maintain compliance without relying on external contractors or hazardous waste transport.

Each HICLOVER unit can be installed in fixed, containerized, or mobile configurations, adapting to space and logistical constraints common in healthcare settings.


Environmental and Safety Benefits

  • Complete combustion with >99% efficiency.

  • Temperature stability through PLC feedback control.

  • Reduced emissions compliant with China GB 18484-2020 and WHO recommendations.

  • Ash residue reduced by up to 95%.

  • Automatic safety lock and false alarm systems to protect operators.

These advantages make HICLOVER incinerators suitable for hospitals operating under international funding frameworks, such as UN, WHO, and World Bank health programs, where reliability and environmental compliance are mandatory.


Partnering for Safer Healthcare Waste Management

HICLOVER’s engineering and export experience cover over 40 countries, supplying medical waste incineration systems tailored to varying regional regulations and fuel availability. The company also provides custom emission control modules through its CloverFilter division, enabling comprehensive waste-to-clean-air solutions.

Explore more at
www.hiclover.com | Medical Waste Incinerator | PLC-Controlled Systems | Contact HICLOVER | Emission Treatment Units


Keywords: medical waste incinerator, hospital waste disposal, dual-chamber incinerator, PLC control system, laboratory waste treatment, infectious waste management, HICLOVER environmental technology.

Mobile: +86-13813931455(WhatsApp)

Email:     sales@hiclover.com     
Email:     hicloversales@gmail.com 

 

2025-11-03/11:01:22

Incinerator Items/Model

HICLOVER TS100(PLC)

 

Burn Rate (Average)

100kg/hour

Feed Capacity(Average)

150kg/feeding

Control Mode

PLC Automatic

Intelligent Sensor

Continuously Feeding with Worker Protection

High Temperature Retention(HTR)

Yes (Adjustable)

Intelligent Save Fuel Function

Yes

Primary Combustion Chamber

1200Liters(1.2m3)

Internal Dimensions

120x100x100cm

Secondary Chamber

600L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Burner Type

Italy Brand

Temperature Monitor

Yes

Temperature Thermometer

Corundum Probe Tube, 1400℃Rate.

Temperature Protection

Yes

Automatic Cooling

Yes

Automatic False Alarm

Yes

Automatic Protection Operator(APO)

Yes

Time Setting

Yes

Progress Display Bar

3.7 in” LCD Screen

Oil Tank

200L

Chimney Type

 Stainless Steel 304

1st. Chamber Temperature

800℃–1000℃

2nd. Chamber Temperature

1000℃-1300℃

Residency Time

2.0 Sec.

Gross Weight

7000kg

External Dimensions

270x170x190cm(Incinerator Main Body)

Burner operation

Automatic On/Off

Dry Scrubber

Optional

Wet Scrubber

Optional

Top Loading Door

Optional

Asbestos Mercury Material

None

Heat Heart Technology(HHT)

Optional

Dual Fuel Type(Oil&Gas)

Optional

Dual Control Mode(Manual/Automatic)

Optional

Temperature Record

Optional

Enhanced Temperature Thermometer

Optional

Incinerator Operator PPE Kits

Optional

Backup Spare Parts Kits

Optional

Mobile Type

Optional:Containerized/Trailer/Sledge Optional

Scroll to Top