Advanced Medical Waste Incineration Systems for Hospitals and Diagnostic Laboratories
Healthcare facilities―including hospitals, clinics, and medical testing centers―generate sensitive waste streams that demand secure and complete destruction. Items such as plastic syringes, disposable protective gear, and laboratory residues pose infection and environmental risks if improperly handled. The HICLOVER dual-chamber incinerator offers a reliable and regulatory-compliant solution for medical waste disposal, combining high-temperature combustion with PLC automatic control for precision and safety.
The Growing Need for Reliable Medical Waste Treatment
As healthcare infrastructure expands across Africa, the Middle East, and Southeast Asia, hospitals and clinics face increasing pressure to comply with modern waste management standards. Regions like Tanzania, Indonesia, and Jordan have seen new testing centers and mobile clinics producing large volumes of infectious waste, often without centralized treatment facilities.
In such contexts, the on-site medical waste incinerator becomes critical. It ensures the complete thermal destruction of sharps, plastics, and contaminated materials while preventing open burning or unsafe disposal practices.
HICLOVER Dual-Chamber Design
The HICLOVER medical incinerator series integrates robust engineering and automation to ensure both operator safety and emission compliance. Each system features:
-
Primary combustion chamber (850C950 °C) for waste destruction.
-
Secondary combustion chamber (≥1100 °C, ≥2 s retention time) for gas purification.
-
PLC automatic control for real-time temperature monitoring and operational safety.
-
High-alumina refractory lining for durability and heat retention.
-
Diesel, LPG, or natural gas burners with adjustable output for energy efficiency.
-
Optional flue-gas filtration units (dry scrubber, quench tower, or bag filter).
These systems ensure complete oxidation, minimize odor and smoke, and maintain stable operation even during continuous hospital waste feeding.
Application in Healthcare and Laboratory Environments
The incinerators are ideal for:
-
Urban and regional hospitals handling mixed medical waste.
-
Rural health centers requiring autonomous, easy-to-maintain solutions.
-
Diagnostic and testing laboratories producing biological samples and contaminated materials.
In Kenya, Cambodia, and Iraq, for example, decentralized incineration systems allow facilities to maintain compliance without relying on external contractors or hazardous waste transport.
Each HICLOVER unit can be installed in fixed, containerized, or mobile configurations, adapting to space and logistical constraints common in healthcare settings.
Environmental and Safety Benefits
-
Complete combustion with >99% efficiency.
-
Temperature stability through PLC feedback control.
-
Reduced emissions compliant with China GB 18484-2020 and WHO recommendations.
-
Ash residue reduced by up to 95%.
-
Automatic safety lock and false alarm systems to protect operators.
These advantages make HICLOVER incinerators suitable for hospitals operating under international funding frameworks, such as UN, WHO, and World Bank health programs, where reliability and environmental compliance are mandatory.
Partnering for Safer Healthcare Waste Management
HICLOVER’s engineering and export experience cover over 40 countries, supplying medical waste incineration systems tailored to varying regional regulations and fuel availability. The company also provides custom emission control modules through its CloverFilter division, enabling comprehensive waste-to-clean-air solutions.
Explore more at
www.hiclover.com | Medical Waste Incinerator | PLC-Controlled Systems | Contact HICLOVER | Emission Treatment Units
Keywords: medical waste incinerator, hospital waste disposal, dual-chamber incinerator, PLC control system, laboratory waste treatment, infectious waste management, HICLOVER environmental technology.
2025-11-03/11:01:22
|
Incinerator Items/Model |
HICLOVER TS100(PLC)
|
|
Burn Rate (Average) |
100kg/hour |
|
Feed Capacity(Average) |
150kg/feeding |
|
Control Mode |
PLC Automatic |
|
Intelligent Sensor |
Continuously Feeding with Worker Protection |
|
High Temperature Retention(HTR) |
Yes (Adjustable) |
|
Intelligent Save Fuel Function |
Yes |
|
Primary Combustion Chamber |
1200Liters(1.2m3) |
|
Internal Dimensions |
120x100x100cm |
|
Secondary Chamber |
600L |
|
Smoke Filter Chamber |
Yes |
|
Feed Mode |
Manual |
|
Burner Type |
Italy Brand |
|
Temperature Monitor |
Yes |
|
Temperature Thermometer |
Corundum Probe Tube, 1400℃Rate. |
|
Temperature Protection |
Yes |
|
Automatic Cooling |
Yes |
|
Automatic False Alarm |
Yes |
|
Automatic Protection Operator(APO) |
Yes |
|
Time Setting |
Yes |
|
Progress Display Bar |
3.7 in” LCD Screen |
|
Oil Tank |
200L |
|
Chimney Type |
Stainless Steel 304 |
|
1st. Chamber Temperature |
800℃–1000℃ |
|
2nd. Chamber Temperature |
1000℃-1300℃ |
|
Residency Time |
2.0 Sec. |
|
Gross Weight |
7000kg |
|
External Dimensions |
270x170x190cm(Incinerator Main Body) |
|
Burner operation |
Automatic On/Off |
|
Dry Scrubber |
Optional |
|
Wet Scrubber |
Optional |
|
Top Loading Door |
Optional |
|
Asbestos Mercury Material |
None |
|
Heat Heart Technology(HHT) |
Optional |
|
Dual Fuel Type(Oil&Gas) |
Optional |
|
Dual Control Mode(Manual/Automatic) |
Optional |
|
Temperature Record |
Optional |
|
Enhanced Temperature Thermometer |
Optional |
|
Incinerator Operator PPE Kits |
Optional |
|
Backup Spare Parts Kits |
Optional |
|
Mobile Type |
Optional:Containerized/Trailer/Sledge Optional |


